32
Copy Group
This feature copies the settings from one group, thereby making it easy to set up a new group with just
minor adjustments.
When setting up a new group for the first time, use the ‘Copy Group’ function to copy Group 0, thereby
creating a new group, and then use the ‘Edit Group’ function to customize the new group.
Clear Group
This feature clears all the functions assigned to a group, effectively disabling all remotes belonging to that
group. It does not, however, delete the remotes so reassigning the functions will re
-
enable the remotes
belonging to the group.
Lock TX Menu
This feature prevents unauthorised users from adding new remotes. Only users in the master group can
add remotes when the Lock TX Menu is enabled. To enable this function a minimum of two remotes must
be programmed to Group 0.
Lock Main Menu
If this function is enabled, only users belonging to Group 0 can make changes to the controller. To enable
this function a minimum of two remotes must be programmed to Group 0.
Lock Receiver
Enabling this feature will lock the onboard receiver. By locking the onboard receiver, any remote that
does not belong to Group 0 will be disabled. Remotes belonging to Group 0 cannot be disabled (see EDIT
GROUP instead).
Erase all Remotes
This function erases all remotes currently programmed to the controller.
PEDESTRIAN ENTRY
Pedestrian Gap
This function allows you to set the distance the gate will travel when opening for pedestrian access. This
can be set from 0.3 to 3m wide.
Pre Open Delay
Use this function to set a 0
-
65 second delay between the activation of Pedestrian Trigger and the actual
opening of the gate to the pedestrian open position. This is useful if a Pedestrian Trigger button is located
some distance away from the gate, such as on an intercom inside the building, and allows the pedestrian
to walk to the gate before it starts opening.
Pre Close Delay
Use this function to set a 0
-
65 second delay between the activation of Pedestrian Trigger and the closing
of the gate from the pedestrian open position. This is useful if a Pedestrian Trigger button is located some
distance away from the gate, such as on an intercom inside the building, and allows the pedestrian to
walk to the gate before it starts closing. A light can be connected to the controller which will give warning
flashes during the set time delay.
Closing Speed
For pedestrian mode, use this function to adjust the closing speed of the gate from between 5 and 20
meters a minute.
PED Closing Force
This function sets the Collision Sensing sensitivity when closing in pedestrian mode. This setting is gener-
ally more sensitive than the normal closing force.
Enable Auto Close
Enabling this function allows the gate operator to Auto Close when in pedestrian mode. If Safety Beams
are connected, the Auto Close Time delay will reset every time the beams are obstructed.
PED Auto Close Time
This feature delays the closing of the gate when in pedestrian mode. The delay can be set from 1
-
600
seconds. If Safety Beams are connected, the timer will reset after the pedestrian has passed through.
Beams Auto Close
This feature closes the gate automatically as soon as the pedestrian has passed through the beams.
Close IR Reverse
If Close IR Reverse is enabled, the gate will reverse back to the pedestrian open position if the Closing
Safety Beam is blocked while the gate is closing. If it is disabled, the gate will stop and not reverse back.
This is used to ‘pinch’ off an entry being used by opportunistic pedestrians.
……..continued
Содержание RT25/50
Страница 6: ...6 TRITEK CONTROLLER SPECIFICATIONS Continues...
Страница 20: ...20 RECEIVER SAFETY BEAM B RECEIVER SAFETY BEAM A MAX LOAD 300mA TWO SETS OF SAFETY BEAMS RELAY OUTPUT...
Страница 21: ...21 RADIO RECEIVER LOOP DETECTOR MAX LOAD 300mA EXTERNAL RADIO RECEIVER LOOP DETECTOR...
Страница 22: ...22 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM CLOSING SAFETY BEAM RELAY OUTPUT CLOSING SAFETY BEAM FET OUTPUT...
Страница 23: ...23 RECEIVER SAFETY BEAM RECEIVER SAFETY BEAM OPENING SAFETY BEAM FET OUTPUT OPENING SAFETY BEAM RELAY OUTPUT...
Страница 26: ...26 ELECTRIC LOCK 3A MAX MAGNETIC LOCK 500mA max 12V 250mA max 24V ELECTRIC LOCK MAGNETIC LOCK...
Страница 51: ...51 NOTES...