DGS-1510/ME Series Metro Ethernet Switch CLI Reference Guide
589
Chapter 71
System Severity Command List
config system_severity
[trap | log | all] [emergency | alert| critical | error | warning | notice | information | debug |
<level 0-7>]
show system_severity
71-1
config system_severity
Description
This command is used to configure the severity level control for the system.
When the user chooses a specific level to log or trap, messages at that severity level or more will be logged or
trapped to SNMP managers.
Format
config system_severity [trap | log | all] [emergency | alert| critical | error | warning | notice | information |
debug | <level 0-7>]
Parameters
trap
- Specifies the severity level control for traps.
log
- Specifies the severity level control for the log.
all
- Specifies the severity level control for traps and the log.
emergency
- Specifies the severity level to 0.
alert
- Specifies the severity level to 1.
critical
- Specifies the severity level to 2.
error
- Specifies the severity level to 3.
warning
- Specifies the severity level to 4.
notice
- Specifies the severity level to 5.
information
- Specifies the severity level to 6.
debug
- Specifies the severity level to 7.
<level 0-7>
- Enter the severity level here. This value must be between 0 and 7.
Restrictions
Only Administrators and Operators can issue this command.
Example
To configure severity level control as information level for trap:
Содержание DGS-1510/ME Series