DGS-1510/ME Series Metro Ethernet Switch CLI Reference Guide
159
Example
To show the CFM Remote MEP information:
DGS-1510-28XMP/ME:admin# show cfm remote_mep mepname mep1 remote_mepid 2
Command: show cfm remote_mep mepname mep1 remote_mepid 2
Remote MEPID : 2
MAC Address : 00-11-22-33-44-02
Status : OK
RDI : Yes
Port State : Blocked
Interface Status : Down
Last CCM Serial Number : 1000
Sender Chassis ID : 00-11-22-33-44-00
Sender Management Address: SNMP-UDP-IPv4 10.90.90.90:161
Detect Time : 2008-01-01 12:00:00
DGS-1510-28XMP/ME:admin#
16-25
show cfm pkt_cnt
Description
This command is used to show the CFM packet’s RX/TX counters.
Format
show cfm pkt_cnt {[ports <portlist> {[rx | tx]} | [rx | tx] | ccm]}
Parameters
ports
- (Optional) Specifies the port counters to show. If not specified, all ports will be shown.
<portlist>
- Enter the list of ports used for this configuration here.
rx
- (Optional) Specifies to display the RX counter.
tx
- (Optional) Specifies to display the TX counter. If not specified, both of them will be shown.
rx
- (Optional) Specifies to display the RX counter.
tx
- (Optional) Specifies to display the TX counter. If not specified, both of them will be shown.
ccm
- (Optional) Specifies the CCM RX counters.
Restrictions
None.
Example
To show the CFM packet’s RX/TX counters:
Содержание DGS-1510/ME Series
Страница 1: ......