DGS-1510/ME Series Metro Ethernet Switch CLI Reference Guide
452
Chapter 53
Peripherals Command List
show device_status
show environment
config temperature
threshold
{high <temperature -500-500> | low <temperature -500-500>}(1)
config temperature
[trap | log] state [enable | disable]
53-1
show device_status
Description
This command is used to display the current status of power(s) and right fan on the system. When any fan is failed,
only the failed fan(s) will display in the fan field. Take DGS-1510-28XMP/ME as an example. DGS-1510-
28XMP/ME has two fans on the right side. If two fans are working normally, the Right Fan field displays “OK”. If the
fan 2 works failed, the Right Fan field displays “2 Fail”.
Format
show device_status
Parameters
None.
Restrictions
None.
Example
To show device status:
DGS-1510-28XMP/ME:admin#show device_status
Command: show device_status
Internal Power: (Not Support)
External Power: None
Right Fan : 2 Fail
DGS-1510-28XMP/ME:admin#
53-2
show environment
Description
This command is used to display current status of power(s) and fan(s) on the system.
Format
show environment
Содержание DGS-1510/ME Series
Страница 1: ......