- CYPRES 2 User’s Guide -
page 53
Data common to Expert, Tandem, Student, Speed, changeable Mode and WSC models:
Length, width, height of the processing unit: ..................................................approx. 85 x 43 x 32 mm
Length, width, height of the control unit: .......................................................approx. 65 x 18 x 6,5 mm
Length, diameter of the release unit: ..........................................................................approx. 43 x 8 mm
Cable length of the release unit (including release unit): ..............................................approx. 500 mm
Storage temperature: ............................................................................................... +71° to -25° Celsius
Storage pressure: ....................................................................200 to 1094 hPa (
5.906 to 32.306 In.Hg)
Working temperature: ......................................................................................... +63° to -20° Celsius *
Maximum allowable humidity: ......................................................................up to 99,9 % rel. humidity
Waterproof: ......................................................... up to 24 hours down to a depth of 8 feet (2.5 meters)
Dropzone offset adjustment limits: ....................±3000 feet or ±1000 m (WSC ±1050 feet or ±350 m)
Operating range below / above sea level: ...................-2140 feet to +26,000 feet (-650 m to +8000 m)
Functioning period: ...........................................................................................14 hours from switch-on
Power supply:...................................................................................................... service life warranty**
Maintenance: ............................................................................................................ see chapter 14.1***
Warranty period: ............................................................................................................... see chapter 15
Service life: .............................................................................................................. see chapter 14.1***
*
These temperature limits do not mean the outside (ambient) temperatures but rather temperatures inside the
processing unit. Therefore, these limits won‘t have any meaning until the processing unit itself has reached the
temperatures in question. In actual fact, these limits will rarely be reached due to the location of the CYPRES in
the reserve container, and the insulating properties of the processing unit pouch and parachute canopies.
** If recommended maintenances have been performed within the scheduled time frames.
*** According to the present knowledge base
.
14. Technical Data
Содержание 2
Страница 63: ... CYPRES 2 User s Guide page 63 Personal Info ...
Страница 64: ...In case someone from the security personnel has concerns ...
Страница 65: ......
Страница 66: ......
Страница 68: ......
Страница 69: ......
Страница 71: ...This page intentionally left blank ...
Страница 72: ...This page intentionally left blank ...