19
Setting Up the miSAN
Cybernetics
UM-MV-86-B1-0801
Network
Management LAN Port (ETH0)
Using the Management LAN port, connect the miSAN-V-Series to your LAN using a CAT
5e or CAT 6 Ethernet cable. Please note that in some configurations the ETH0 port may
be located in a different position than shown in the above illustration. Each port is clearly
labeled.
iSCSI Network Ports (ETH1, ETH2)
Using one or both iSCSI network ports, connect the miSAN-V-Series to your LAN, Gigabit
Ethernet switch or backup server using a CAT 5e or CAT 6 Ethernet cable. Please note
that in some configurations the ETH1 and ETH2 ports may be located in a different posi-
tion than shown in the above illustration. Each port is clearly labeled.
Power
Using the AC socket on both power supplies, connect the miSAN-V-Series to a readily
accessible AC power source using a standard 3-prong power cord for each socket.
Connecting Power to an Uninterruptible Power
Supply (UPS)
You should use an Uninterruptible Power Supply (UPS) rated to at least 460 watts with
the miSAN-V-Series. This will ensure data buffered in the RAM cache will get written to
disk during a power outage. Use both power supplies when connecting the miSAN-V-