Telnet Menu System
107
UM-MV-86-B1-0801
Cybernetics
The “Main Menu” and each submenu include an item marked:
x) Exit
If if any changes are made to the information, the changes are not committed until after
leaving the menu system. The exit item will change to a pair of menu items:
s) Save changes and exit
x) Discard changes and exit
Type
s
or
x
as desired, to exit the menu with changes saved or not.
Example: to change the hostname for the unit:
1. At the initial screen, type
m
to bring up the “Main Menu.”
2. At the Main Menu, type
2
to bring up “Network Configuration.”
3. Type
1
to bring up the Hostname entry. This will display the current hostname (default
is “
cyberasp
”).
4. Enter the desired hostname, and press
ENTER
. This will change the hostname display,
and return to the “Network Configuration” menu.
5. Type
s
to save the change and exit from the menu. The message “
Changes saved
” will
be displayed briefly; then the initial screen will return.
SCSI configuration
This menu is used to set up SCSI and iSCSI connections. Items 1, 2, and 3 are set up as
described in “SCSI HBA Ports” on page 54.
Configure iSCSI hosts
Assign virtual devices to hosts
Use this sub-menu to control host access to virtual devices.
Содержание miSAN-V6
Страница 104: ...104 Operating the Web Control Panel Cybernetics UM MV 86 B1 0801 ...
Страница 110: ...110 Telnet Menu System Cybernetics UM MV 86 B1 0801 ...
Страница 146: ...146 Packing and Shipping Instructions Cybernetics UM MV 86 B1 0801 ...
Страница 174: ...174 Cybernetics UM MV 86 B1 0801 ...
Страница 182: ...182 Cybernetics UM MV 86 B1 0801 ...
Страница 184: ...184 Cybernetics UM MV 86 B1 0801 ...