Channel
Ê
5.735 GHz
5.765 GHz
5.795 GHz
5.825 GHz
code 0
0 1 2 3
code 1
4 5 6 7
code 2
8 9 A B
code 3
C D E F
Table 6: 5.8G Low Band – Frequency/Code Switch Matrix
Channel
Ê
5.750 GHz
5.780 GHz
5.810 GHz
5.840 GHz
code 0
0 1 2 3
code 1
4 5 6 7
code 2
8 9 A B
code 3
C D E F
Table 7: 5.8G High Band – Frequency/Code Switch Matrix
3.2.1 Selecting the CPE Time Slot
Up to (4) CPE units can communicate with each Base unit when used in a STAR
topology. To distinguish between the four CPEs, a different time slot is allocated to each
CPE using the rotary DIP switch located immediately behind the LEDs as shown in the
figure below. Use a
non-conductive
trim tool to select time slots 0, 1, 2 and 3 to avoid
shorting any components. Reset the unit to put your selection in effect by pressing the
reset button located behind the second white three pin connector as shown.
CPE Time
Slot
Selector
Reset
Button
Figure 148: CPE Time Slot Selection Switch
Trailblazer Installation and User Manual
20