background image

6.2 System Specifications 

 

Air Interface 
 
Data Throughput Rate 
End-to-End System Latency 
Fax Compatibility 
Modem Performance 
 

RF Performance 

Frequency Range  
 
RF Channels 
 
RF Output Power  
 
Receive Sensitivity 
 
External Antenna Port 
 

Environmental Specifications 

Operating Temp 
Humidity 
 
Voltage Requirements  
 
Operating Current 
 

CPE Terminal (FXS) Specifications 

Regulatory 
Open Loop Voltage 
Loop Current 
Maximum Loop Length 
Ringing Voltage 
Ringing Load 
Ringing Waveform 
 
Nominal Transmit Level 
Nominal Receive Level 
2 Wire Port Return Loss 
Voltage Requirements 
Operating Current: No Load, Full Load 
 

Base Unit Specifications 

Regulatory  
 
Maximum Loop Length 
Ring Equivalent Number 
Ring Detect Threshold 
2 Wire Port Return Loss 
Operating Voltage 
Operating Current: No Load, Full Load 
 

Certifications 

 

Warranty 
 

*Proprietary DSSS CDMA using a negotiated QOS with 

Time Division Duplexing  

512, 256, 128, 64 kbps, Configurable with GUI 

Less than 4.4 ms Depending on Speed Selected 

G3 (9.6kbps) and G4 (14.4kbps) 

V.34 (33kbps) via POTS, up to V.90 (56kbps) via 

RuralConnect™ 

 

2.4GHz Standard. 4.9 and 5.8 GHz Options Available  

4 sub channels in 2.4 GHz band,  

8 sub channels in 5.8 GHz 

17dBm typical in 2.4 GHz, 17dBm in 5.8 GHz  

 

-93 dBm/256 kbps @10-6 BER -90 dBm/512 kbps @10-

6 BER  

“N” Type Female 

 
 

-30 to +60 Degrees C (Ambient with Solar Shielding) 

0 to 90% - Non-Condensing 

 
 

Filtered DC nominal 12 to 24 V Negative Earth Ground 

2 Watts Minimum, 8 Watts Maximum Configuration 

 
 

LSSGR, TR57, ITU Q.552, and G.712  

36 to 48V 

20 mA  to 24 mA  

1200 Ohms Including Instrument 

60 VAC RMS  

3 REN 

Balanced Sinusoidal, 20 Hz Standard, Factory 

Programmable 16 to 33Hz  

0.0 dBm0, Factory Programmable  

-2.0 dBm0, Factory Programmable 

24 dB min. 

Filtered DC Nominal 12 to 24V 

1.4 Watts (i.e. 24v @ 60ma) Idle, 4 Watts (i.e. 24v @ 

200ma) max Including Radio 

 

TIA/EIA/IS-968 (FCC), UL 1950, UL 60950, EN 60950, 

IEC60950, EN55022B 

1500 ohms or 18 ma. 

0.3B per line  

24-110Vrms, 17-34 Hz 

24dB min. 

Filtered DC Nominal 12 to 24V 

Less then 2 Watts (i.e. 24v @ 200ma) with 8 Lines 

Active Including Radio 

 

US, Canada, Brazil, Mexico, Philippians’ Islands, 

Morocco 

1 Year Parts and Labor 

 

                Trailblazer Installation and User Manual                                        

40

 

Содержание Trailblazer TB 2.4-5.8 Series

Страница 1: ...Installation User Manual Trailblazer Digital Radio TB 2 4 5 8 and TB 4 9 series Part Number 490 2000 Rev 3 07...

Страница 2: ...products shall be limited to those commitments to the purchaser set forth in its Standard Terms and Conditions of Sale for a delivered product The use of this manual is also limited to the terms and c...

Страница 3: ...vice failure maintain proper grounding during configuration repair or maintenance This is achieved through the use of an antistatic wrist strap securely connected to chassis ground Do not use conducti...

Страница 4: ...OPA TB49 Industry Canada CS 03 3448A 10241A Model TB 2 4 5 8 FCC Reg No Part 68 BMD8 USA 27773 PT E FCC Reg No Part 15 FCCID OPA TB24 58 Industry Canada CS 03 3448A 10241A Industry Canada RSS 210 3448...

Страница 5: ...e product Product Name Trailblazer TB 2 4 5 8 Conforms to the following standard s or other normative document s EMC FCC Part 15 247 And also declares that the product Product Name Trailblazer TB 4 9...

Страница 6: ...1 2 3 4 Connecting Leased Lines 13 2 3 5 Repeater Operation 14 3 Operation 15 3 1 Configuring and Accessing the Trailblazer Unit 15 3 1 1 Connecting the Serial Cable 15 3 1 2 Installing the CWT GUI on...

Страница 7: ...2 1 Installation of Software Firmware Upgrades 39 6 Appendix 39 6 1 About Carlson Wireless 39 6 1 1 Mission 39 6 1 2 History 39 6 1 3 Summary 39 6 2 System Specifications 40 6 2 1 Block Diagram 41 6...

Страница 8: ...cal Tape 31 Figure 27 Gas Discharge Protector Dimensions 34 Figure 28 Shorted Stub Protector Specifications 35 Figure 29 Shorted Stub Protector Dimensions 35 Figure 30 Primary Telephone Line Transient...

Страница 9: ...3 Serial Data Cable Pinout 43 Table 14 Bill 44 Table 15 18dBi Directional Panel Specifications 46 Table 16 24dBi High Gain Parabolic Grid Antenna Specifications 47 Trailblazer Installation and User Ma...

Страница 10: ...nt and point to multipoint applications Applications include Security Monitoring Cameras Public Safety Leased Line Replacement Internet Caf s and Telephone Calling Centers Point to Point Commercial Da...

Страница 11: ...plication with a Windows PC and serial COM port you can configure the amount of bandwidth allocate voice and data channels select different frequencies and CDMA codes use antenna alignment aids and ot...

Страница 12: ...ed while reserving maximum RF bandwidth 1 2 2 General Specifications Note More technical details are found in the Appendix to this manual Product Description Digital Microwave Radio with POTS Leased L...

Страница 13: ...ired and or extended with PVC piping hidden behind drywall The introduction of PVC material disrupts the material s conductivity and thus renders it unacceptable as a ground In desert areas where grou...

Страница 14: ...portance Fresnel Zone The first Fresnel Zone is the football shaped volume area around the line of sight that radio waves spread into after they leave the antenna Trees buildings mountains and any num...

Страница 15: ...cept all other signals within the band interfering or not Devices operating in this band can become a source of interference for Trailblazer products If the interfering signal is stationary and has a...

Страница 16: ...dB 5 5 dB 6 0 dB 5 8 inch Heliax 2 8 dB 4 2 dB 4 7 dB 7 8 inch Heliax 2 1 dB 3 2 dB Not recommended Table 2 Coax Cable Loss Table 2 1 8 2 1 9 Audio and Data Cable Recommendations Standard telephone tw...

Страница 17: ...UI Mounting Hardware optional Optional Power Supplies if ordered will be pre installed in the enclosures Optional Surge Protectors RF and phone lines Antennas optional Optional Batteries if ordered wi...

Страница 18: ...the battery wires Place the battery into the Trailblazer with the positive terminal toward the outside of the enclosure Secure the battery with the battery bracket and the hardware supplied as shown i...

Страница 19: ...onnecting POTS Lines Connect POTS lines as shown in the figure below using the black screw terminals on the units interface card Remember to connect the telephone line s from the phone company to the...

Страница 20: ...Base and CPE units Screw Terminals Figure 5 Telephone Line Connections To connect POTS lines with a rack mount enclosure see figure 5 Pins 4 and 5 on the RJ 45 connector are used for POTS lines Trail...

Страница 21: ...ee photo below RJ45 connector Figure 6 Telephone or Lease Line Connections See figure below for pin out information 1 2 3 4 5 6 7 8 Top view E TX RX TX M RX Audio out of TB Audio into TB Audio out of...

Страница 22: ...t The E lead floats at 5VDC and the driving circuit must sink 3 mA The M lead can sink 75 mA at 60V 2 3 5 Repeater Operation The repeater is used to work around obstructions or to extend the range of...

Страница 23: ...er Unit 3 1 1 Connecting the Serial Cable You can access your Trailblazer with the GUI program included on the Carlson Wireless product CD and the included serial cable Simply plug the DB 9 connector...

Страница 24: ...on Wireless Trailblazer GUI ver x xx Using the GUI Double click the Carlson Wireless icon and choose the appropriate COM port connected to your serial cable After you have selected the correct COM por...

Страница 25: ...2 GUI Showing Status of a CPE The figure to the left Figure 13 shows what the screen will look like for a base unit Select CPE O for Point to Point Click on the Terminal tab to monitor status view and...

Страница 26: ...CARD APPxxx hex file Select the file and click Open to start downloading Figure 13 GUI Showing File Browser The new CPE and Base unit software will take about one minute to download The firmware takes...

Страница 27: ...and the white three pin connectors The tables below show the switch settings for the 16 frequency code combinations for each band currently offered Channel 2 412 GHz 2 432 GHz 2 452 GHz 2 472 GHz code...

Страница 28: ...te with each Base unit when used in a STAR topology To distinguish between the four CPEs a different time slot is allocated to each CPE using the rotary DIP switch located immediately behind the LEDs...

Страница 29: ...ent mounting applications Figure 19 Wall mounting the Trailblazer enclosure Wall Mounting Instructions Attach the mounting flanges to the enclosure using the 20 x 1 bolts flat washers lock washers and...

Страница 30: ...ghten Position the enclosure on the pole Place the U bolts around the pole and slide the pipe flanges over them with the serrated sides facing the pole See figure 19 above Apply an anti seizing compou...

Страница 31: ...warranty and may expose the end user to legal and financial liabilities Regulations regarding maximum antenna gains vary from country to country It is the responsibility of the end user to operate wi...

Страница 32: ...e antenna gain is 18 6 12dBi above 6 or 12 3 or 4 times 3dB above 6dB Checking to see if the transmit power meets the rule is done by subtracting 4 from 30dB equaling 26dBm This transmitter output RF...

Страница 33: ...siderations are important Corner exit RG 58 U pig tail design permits the panel to be mounted in vertical or horizontal polarity Adjustable heavy duty mounting brackets provide maximum flexibility sta...

Страница 34: ...ngle can be made after the antenna has been mounted to the mast Spacing references for downtilt L1 L2 will be as shown left Spacing references for uptilt L1 L2 will be opposite as shown O n the instal...

Страница 35: ...connector Rugged lightweight and waterproof Heavy duty adjustable mounting brackets for 1 to 2 5 inch diameter poles that provide stability even in high wind conditions Unpacking Despite careful packa...

Страница 36: ...he dipole for Vertical Polarity Installing the mount for Horizontal Polarity Installing the dipole for Horizontal Polarity Figure23 Mounting of 24dBi High Gain Parabolic Grid Gain Antenna horizontal o...

Страница 37: ...rable and easy to service if it needs to be removed You will need Electrical tape Rubber tape butyl a thick sticky sealing tape commonly known as vapor wrap We recommend 3M 3339 tape Step 1 Connect Ca...

Страница 38: ...e weather proofing much faster easier and less messy 2 Tightly wrap the connectors with two layers of vapor wrap Note The vapor wrap should seal entire connection and extend 1 5 inches beyond N type M...

Страница 39: ...lose in alignment do the antennas need to be 10 degrees will be adequate for most paths using a 14dBi gain antenna With high gain antennas 1 degree may be necessary Alignment indicators Due to the nat...

Страница 40: ...e telephone network must be protected from these current surges by a two stage protection network primary protection and secondary protection The secondary protection is internal to the Trailblazer an...

Страница 41: ...be grounded by connecting a ground wire usually 8 AWG solid to the ground screw on the body of the surge protector The other end of the ground wire must tie into the tower ground system In line light...

Страница 42: ...e protector shorted stub Maximum power 50 Ohms 100 W Power Handling 8 20 s waveform 50 kA Power Handling 1 2 50 s waveform 70 kA VSWR 4 2 5 0 GHz 1 3 1 VSWR 5 6 6 0 GHz 1 2 1 Impedance 50 Ohms Frequen...

Страница 43: ...Figure 29 Shorted Stub Protector Specifications Figure 30 Shorted Stub Protector Dimensions Trailblazer Installation and User Manual 35...

Страница 44: ...ection on the CPE is active protection and only works when the CPE is powered up If the CPE is ever left un powered the phone antenna and power lines should all be disconnected to protect the circuitr...

Страница 45: ...LL system waits to receive a signal from the base When the CPE receives a signal it checks to ensure that the SFD code matches its own SFD code If the codes match the CPE begins adjusting its oscillat...

Страница 46: ...ging operation ALIGNMENT Off Blinks Solid Off Blinks Solid Final alignment minimizing bit errors LOCKED Off Off Flashing Off Off Flashing Units locked and aligned ready for service PACKET ERRORS Off B...

Страница 47: ...ostics details 6 Appendix 6 1 About Carlson Wireless Mission Carlson Wireless Technologies Inc CWT is dedicated to designing manufacturing and marketing innovative low power digital WLL wireless local...

Страница 48: ...3 9 6kbps and G4 14 4kbps V 34 33kbps via POTS up to V 90 56kbps via RuralConnect 2 4GHz Standard 4 9 and 5 8 GHz Options Available 4 sub channels in 2 4 GHz band 8 sub channels in 5 8 GHz 17dBm typic...

Страница 49: ...using the diagram below 6 3 1 Configuration Port Pin Out Configuration Port Cable Construction Table A DB9 pin Female to be fit in the PC is wired with A 3 pin 100 spacing connector female connecting...

Страница 50: ...d RI on pin 9 not used Table 12 Configuration Port Cable Construction Table GROUND RECEIVE TRANSMIT Figure 34 Serial Data Cable PinOut PCB View Standard AT PinOut for a DB9 Connector Figure 35 Serial...

Страница 51: ...o PC 6 4 Signal Strength Conversion Chart Carlson Wireless Trailblazer Rev 6C Radios Radio threshold 90 dBm 512 kbps Radio threshold 93 dBm 256 kbps GUI Signal Reading Path Attn dB Rx Level Fade Margi...

Страница 52: ...73 59 31 34 39 72 58 32 35 40 71 57 33 36 41 70 56 34 37 42 69 55 35 38 43 68 54 36 39 44 67 53 37 40 45 66 52 38 41 46 65 51 39 42 47 64 50 40 43 48 63 49 41 44 49 62 48 42 45 50 61 47 43 46 51 60 4...

Страница 53: ...6 5 1 18dBi Directional Panel Plots and Specs Figure 36 18 dBi Antenna Patterns Trailblazer Installation and User Manual 45...

Страница 54: ...48 In mm Wind Load 85 100MPH Frequency Range 2300 2500 MHz 3 deg beam width 19 vertical 18 horizontal deg Front to Back 25 dB VSWR 1 6 1 Impedance 50 ohms Input Power 20 watts Operating Temperature 40...

Страница 55: ...Weight 11 5 Lbs kg Dimension W x L 28 5 x 36 724 x 914 In mm Wind Load 41 100MPH Frequency Range 2400 2485 MHz 3 deg beam width 8 vertical 10 horizontal deg Front to Back 25 dB VSWR 1 5 1 Impedance 5...

Страница 56: ...ducts not supplied by Carlson It also does not cover failures which result from accident misuse abuse neglect mishandling misapplication alteration modification lightning power line surge introduction...

Страница 57: ...peed data link control IP internet protocol ISDN integrated services digital network ITU International Telecommunications Union Kbps kilobits per second LAN local area network LED light emitting diode...

Страница 58: ...e central office regenerates digital signals and monitors them for problems and provides a way of testing a digital circuit CLASS features Acronym for Custom Local Area Signaling Services consists of...

Страница 59: ...ength addresses ISDN Acronym for Integrated Services Digital Network It is a network architecture that enables end to end digital connections It supports diverse services through integrated access arr...

Страница 60: ...ntrol and reporting scheme widely used to manage devices from different vendors and operates on top of the Internet protocol switched network Is a network of dial up telephone lines that uses circuit...