Digital Outputs
The Tritex II 90 mm and 115 mm have 4 optically isolated digital
outputs. These outputs are sourcing only, they provide a positive voltage
when on. Each output can be assigned to any of the internal output
functions. (See Software Manual) Outputs are individually short circuit
protect at 500mA and thermally protected against overload. These
outputs can absorb the energy in an inductive “kick” at turn-off up to
0.5 Joule, so an external freewheeling diode would be needed only in
rare cases.
Do not overload outputs.
Outputs are rated at 100 mA continuous. An overloaded
output will cycle off and on to protect itself, which will send
an incorrect signal to other system components.
External wiring of outputs for connection to PLC
Output Circuit (internal)
CAUTION
Field I/O +
Output 1-4
Field I/O Comm
10kΩ
Field I/O +
+
I/O Supply
24 V
-
Output (1-4)
I/O
Connection
PLC Input
Содержание EXLAR Tritex II AC
Страница 12: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 11 UL Certificate of Compliance ...
Страница 15: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 14 ...
Страница 16: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 15 ...
Страница 20: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 19 ...
Страница 21: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 20 ...
Страница 33: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 32 T2M X090 Actuator Mounting Dimensions ...
Страница 34: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 33 T2M X115 Actuator Dimensions ...
Страница 35: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 34 R2M090 and R2G090 Motor Gearmotor Dimensions ...
Страница 36: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 35 R2M115 and R2G115 Motor Gearmotor Dimensions ...
Страница 37: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 36 Options and Rod End Attachment Dimensions ...
Страница 38: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 37 ...
Страница 86: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 85 ACCESSORIES Cables T2IOC xxx I O Cable ...
Страница 87: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 86 T2IPC xxx Power Cable ...
Страница 88: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 87 TTICO xxx Communications Cable ...