Power Terminal Wiring
Use Correct Wires and Terminations for Power Wiring.
L1, L2,PE, R1 and R2 connections should be 14 AWG / 2.5
mm, 300V,105
⁰
C minimum.
Smaller gauge wires can be used on the C+ and C-
terminals for convince see Control Logic Power Supply
section below. If ferrules are used with 14 AWG wire a precise crimp is
required. The crimped ferrule must measure less than 2.1 mm on each
side of the ferrule or it will not fit into the terminal opening.
The terminals are lever actuated spring terminals that retain high and
constant contact force on any wire through thermal cycling. To operate,
place a small flat bladed screwdriver in the indentation in the lever. Press
down on the lever at approximately a 45
⁰
angle with only enough force to
open the clamp, the clamp will full open with about 8 lbs of force, insert
the wire, and release the force on the lever. Check that the wire is in
position with insulation partly into the lead-in window, but not into the
clamp area.
Do not apply direct vertical force or excess force on the
terminal levers. A force of 8 lbs at a 45
⁰
angle is sufficient
to fully open the wire clamp, applying a force in excess of
12lbs can damage the terminal.
Opening spring terminals on Power Connector
CAUTION
CAUTION
45
⁰
Содержание EXLAR Tritex II AC
Страница 12: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 11 UL Certificate of Compliance ...
Страница 15: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 14 ...
Страница 16: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 15 ...
Страница 20: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 19 ...
Страница 21: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 20 ...
Страница 33: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 32 T2M X090 Actuator Mounting Dimensions ...
Страница 34: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 33 T2M X115 Actuator Dimensions ...
Страница 35: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 34 R2M090 and R2G090 Motor Gearmotor Dimensions ...
Страница 36: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 35 R2M115 and R2G115 Motor Gearmotor Dimensions ...
Страница 37: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 36 Options and Rod End Attachment Dimensions ...
Страница 38: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 37 ...
Страница 86: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 85 ACCESSORIES Cables T2IOC xxx I O Cable ...
Страница 87: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 86 T2IPC xxx Power Cable ...
Страница 88: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 87 TTICO xxx Communications Cable ...