44
Expert-32P rev.11
Expert-32P
Curtain’s Opening Times:
The curtain’s opening times are associated with the activation of fan stages.
When the start temperature of a tunnel fan stage is reached, the curtain
opens according to the opening time that is associated with that stage.
Curtain is Fully Opened at Stage:
When the start temperature of this stage is reached, the curtain fully opens
and remains opened up until the temperature decreases below the stage's
stop temperature.
CURTAIN: BASED ON THE STATIC PRESSURE
PRINCIPLE OF OPERATION
Tunnel Ventilation’s Beginning:
The user defines a stage at which the tunnel ventilation mode starts. When
the start temperature of this stage is reached, the tunnel curtain opens
during the pre-opening delay. The stage's fans are then activated. Once
the curtain's pre-opening is done, the tunnel curtain becomes controlled by
the static pressure level as follows:
When the static pressure level exceeds the high pressure set point, the
curtain opens during the
Open Time then stays still during the Off Time. This
process is repeated up until the static pressure level goes back to the desired
TIME
STATIC
PRESSURE
HI SET
POINT *
THE STATIC PRESSURE
LEVEL DECREASES
BELOW THE LO SET POINT:
THE CURTAIN CLOSES
ACCORDING TO A TIMER
(CLOSE TIME/ OFF TIME)
THE CURTAIN
STOPS CLOSING
THE STATIC PRESSURE
LEVEL EXCEEDS
THE HI SET POINT:
THE CURTAIN OPENS
ACCORDING TO A TIMER
(OPEN TIME/ OFF TIME)
CURTAIN
STOPS
OPENING
CUR
T
A
IN
OP
E
N
S
CU
RT
AIN
ST
A
Y
S
STI
L
L
CU
RT
AI
N
CL
O
S
E
S
* THE HIGH AND LOW SET POINTS
CAN AUTOMATICALLY
BE ADJUSTED BASED ON
THE OUTSIDE TEMPERATURE
LO SET
POINT*