30
Expert-32P rev.11
Expert-32P
ON 1m30 curveOFF
Cycle 5m00
1
Adjusting Timer Settings
The fans' running time, within the minimum ventilation cycles ranges
from 0 to 99 minutes, 59 seconds and cannot be greater than the cycle
time. The cycle time ranges from 0 to 99 minutes, 59 seconds. A
separate running time can be defined for night.
Set the function to
MINIMUM
VENTILATION / CURVE
using the
menu select buttons. The current
on time, cycle time and curve on/
off state are displayed.
If the curve is ON, press the Edit key. The on/off state of the curve
flashes on the display. Use the arrow keys to turn the curve off.
Press the Edit key once again and follow the instructions below.
If the curve is OFF, press the Edit key. The on time minutes flash on
the display. Use the arrow keys to adjust the on time minutes to the
desired value.
Press the Edit key. The on time seconds flash on the display. Use the
arrow keys to adjust the on time seconds to the desired value.
Press the Edit key. The cycle time minutes flash on the display. Use
the arrow keys to adjust the cycle time minutes to the desired value.
Press the Edit key. The cycle time seconds flashes on the display.
Use the arrow keys to adjust the cycle time seconds to the desired
value.
Press the down-arrow key. The
night on time is displayed.
Press the Edit key. The night-time
on time minutes flash on the display. Use the arrow keys to adjust
the night on time minutes to the desired value.
Night
on time 1m30