50
Expert-32P rev.11
Expert-32P
Press the down-arrow key in order
to select the "
Opening Time
"
display. Note that this menu only
appears if the tunnel curtain is con-
trolled by the static pressure (see Controller Setup).
Press the Edit key then use the arrow keys to adjust the curtain's
opening time to the desired value. Press Edit to validate.
Press the down-arrow key once. The closing time is displayed.
Press the Edit key then use the arrow keys to adjust the curtain's
closing time to the desired value.
Press the down-arrow key once again. The OFF time is displayed.
Press the Edit key then use the arrow keys to adjust the curtain's OFF
time to the desired value. Press Edit to validate.
7
Adjusting the Pre-Opening Delay
This delay is used to open the tunnel curtain before the activation of the
first tunnel fans. The pre-opening delay can be adjusted from 0 to 120
seconds.
Set the function to
START/STOP TEMPERATURE
using the menu select
buttons. The start and stop temperatures for Heater 8 are displayed
and the Heater 8 LED on the right flashes.
Use the output select buttons to
select
TUNNEL CURTAIN – OPEN
.
The corresponding LED on the right
of the front panel flashes.
Press the down-arrow key in order
to display the pre-opening menu.
Note that this menu only appears if
the curtain is controlled by the static
pressure level (see Controller Setup).
Press the Edit key then use the arrow keys to adjust the tunnel curtain's
pre-opening time to the desired value. Press Edit to validate.
First stage: 9
PreOpening Fan
Delay: 45sec
Opening Time:
90sec