49
Expert-32P rev.11
Expert-32P
Use the output select buttons to
select
TUNNEL CURTAIN – OPEN
.
The corresponding LED on the right
of the front panel flashes.
Press the down-arrow key in order
to display the winter's static pres-
sure set points. Note that this menu
only appears if the curtain is
controlled by the static pressure level (see Controller Setup).
Press the Edit key then use the arrow keys to adjust the Winter's Lo
static pressure set point to the desired value. Press the Edit key once
again to validate and to step to the next item. Winter's high static
pressure set point is flashes on the display.
Use the arrow keys to adjust Winter's Hi static pressure set point to
the desired value. Press Edit to validate.
Press the down-arrow key to display Summer's pressure set points. Pro-
ceed in similar fashion to adjust the summer set points.
Note that the summer set points are only used if an outside temperature
probe is enabled. Otherwise, the controller permanently operates
according to Winter's static pressure set points.
6
Adjusting Curtain's Static Pressure Timer
When controlled by the static pressure, the curtain moves according to a timer
(Open Time, Close Time, Off Time). The tunnel curtain starts moving according
to a timer whenever the static pressure level exceeds the hi or lo set points.
Set the function to
START/STOP TEMPERATURE
using the menu select
buttons. The start and stop temperatures for Heater 8 are displayed
and the Heater 8 LED on the right flashes.
Use the output select buttons to select
TUNNEL CURTAIN – OPEN
.
The corresponding LED on the right of the front panel flashes.
First stage: 9
Setp in winter
Lo .02" Hi .05"
Содержание Expert-32P
Страница 1: ...Expert 32P Temperature Controller USER S MANUAL...
Страница 7: ...7 Expert 32P rev 11 LOCATION OF THE CONTROLS...
Страница 74: ......
Страница 75: ......
Страница 76: ...REV 01 M 890 00073 rev 11...