17
Expert-32P rev.11
Expert-32P
Relays 1-8
12345678
Relays 9-16
90123456
Relays 17-24
78901234
RELAY ASSIGNMENTS
The user can now configure each output separately by selecting the
output using the output select buttons and adjusting the parameters
displayed. Configuration parameters vary according to the type of
output.
Use the up- and down-arrow keys to step through all the display screens
for a given output. The last display screen for all outputs is the relay
assignment.
Relay Assignments
: The Expert-32P
can control up to 32 output relays.
The relay panel contains 32 relay
outputs. The mapping between the
stages and the relays must be deter-
mined by the user. The relays are
displayed in groups of 8 relays at a
time. The relays assigned to an output
correspond to the flashing numbers on
the display. Press the Edit key to
display each relay state and use the
arrow keys to assign (ON) or unassign
(OFF) the relay. Use the down-arrow
key to step to the next bank of relays
(see example on following pages).
Use the template at the end of this
manual to map the relays before
assigning them from the front panel.
Relays with Timer on Fan Stages 2-10
: For these fan stages, the user
can configure certain relays to operate in timer mode for cooling while
other relays operate in on-off mode. Fan stages 1 and 2 are used for
minimum ventilation. When you configure these stages, the message
«Stage used for min. ventilation» is displayed to remind the user that
relays for these stages cannot be configured in timer mode.
Relays 25-32