Set the function to
VENT DOORS
using the menu select buttons.
Winter's high and low pressure set points are displayed.
Press the down-arrow key twice.
The outside temperature below
which the winter settings start
being used is displayed.
Press the Edit key. Winter's start temperature flashes on the
display. Use the arrow keys to adjust it the desired value.
Press the down-arrow key. The outside temperature above which
the summer settings start being used is displayed.
Press the Edit key. Summer's start temperature flashes on the
display. Use the arrow keys to adjust it to the desired value.
4
Adjusting the Wind Delay
When the pressure level exceeds the high or low static pressure set points,
the vent doors start opening or closing continuously right after the wind
delay is elapsed. The high or low pressure condition must be maintained
during this delay for the vent doors to start moving. This avoids opening or
closing vent doors if a wind draft causes temporary variations in the pres-
sure level.
Set the function to
VENT DOORS
using the menu select buttons.
Winter's high and low pressure set points are displayed.
Press the down-arrow key to select
the wind delay display.
Press the Edit key. The delay flashes on the display. Use the arrow
keys to adjust it to the desired value.
Outside T° in
Winter 5.0°F
Wind delay: 15 sec