4.11
Installation examples
4.11.1
Inverter connection using analog output.
In the example above, you can see the simplest connection of an inverter to operate spindles in an
engraving plotter.
CSMIO/IP-S outputs in use:
CSMIO/IP-S signal
Connector on CSMIO/IP-S
PIN numbers on
CSMIO/IP-S (v2)
connector
Inverter function
Analog GND connection
DB9 – Analog I/O
2
AGND – reference potential for
analog input of a speed command
Analog output 0
DB9 – Analog I/O
1
AGND – reference potential for
analog input of a speed command
CSMIO/IP digital outputs Power
GND
DB25 – Digital outputs (0-15)
17
Outputs 4 and 5 power
DB25 – Digital outputs (0-15)
4
24V output for controlling signals
Digital output 4
DB25 – Digital outputs (0-15)
5
Right revs switching
Digital output 5
DB25 – Digital outputs (0-15)
18
Left revs switching
Do no forget to set the configuration parameters of the inverter properly. Incorrect settings may
cause - in the best case - the inverter error, in the worst - the spindle motor becomes
permanently damaged (such damage is not covered by warranty).
Mach3 program configuration, concerning use of a spindle with revs control was described in
chapter 10 - "Mach3 Configuration".
C S - L a b s . c . – C S M I O / I P - S - C N C C o n t r o l l e r
Page 29