10.9.6.4
Safety Extras
In CSMIO/IP software few additional functions were implemented, which increase safety and comfort
of work.
Auto Z-Inh Enable
Automatic Z-axis move limitation. Enables protection against
worktable of a machine damage. More details in chapter
14.1 – Automatic Tool Length Measurement.
Smart Limits
Movement blocking when hardware limit signal is active. It
works the way that e.g. when X++ signal is active, then we
can move X-axis only in „-„ direction.
Probe protection
Tool length sensor protection. When Probe signal is active
then Z-axis manual jog in „-„ (down) direction is blocked.
If Probe signal goes active during treatment, a machine will
be stopped just like in situation when E-Stop is pressed on.
10.9.6.5
CSMIO Connection Properties – additional connection options
Default MAC
Default MAC address for a connection. It is useful if in our
local network, there are few CSMIO/IP controllers and we
do not want to select a controller we want to connect with
at every Mach3 start. It is set by „Set as Default” button and
reset using „Clear Default”.
Connected MAC
Information about MAC address of currently connected
CSMIO/IP controller.
Name
Currently connected controller name. You can name it by
yourself. The name will also be displayed in controller's se-
lection window if in local network there is more than one
CSMIO/IP controller. To give your name you must enter it
and click „Change Name”.
Clear Default
Default MAC address deletion.
Set as Default
Default MAC address setting.
Change Name
Private name setting for connected CSMIO/IP controller. It
can be any name. However, it cannot contain spaces or spe-
cial characters - e.g. „Lathe01”.
C S - L a b s . c . – C S M I O / I P - S - C N C C o n t r o l l e r
Page 72