1.3
Standards compliance
CSMIO/IP-S controllers were designed and made in accordance with national and international
standards for industrial control systems based on electronic components:
•
Detailed requirements for programmable controllers: working characteristics, shock re-
sistance, safety etc. EN61131-2 (IEC1131-2), CSA 22.2, UL508
•
Compliance with European Guidelines (low voltage, level of electromagnetic interference
Electromagnetic Compatibility
), the CE marking.
•
Electrical and non-combustible properties of insulation materials: UL 746C, UL 94, etc.
•
The Product made in lead-free technology, RoHS compliant.
1.4
Specification
Parameter
Value
Number of digital inputs
32
Number of digital outputs
16
Number of analog inputs
4
Number of analog outputs
2
Supply voltage
24VDC +/-10%
Power consumption
5W
Maximum voltage on in/out lines
30VDC
Maximum load of an output line
250mA
A voltage range of analog inputs
0-10VDC
Maximal load of analog output
5mA
Axis drives control type
(STEP/DIR)
Maximum frequency of a STEP signal
4MHz
Fill factor of the STEP signal
50%
PC connection
Ethernet 10/100Mb
Ambient temperature range
0
o
C to +60
o
C
Relative humidity
10% do 95%
(without condensation)
The STEP outputs signals frequency are in no way limited by the „Kernel speed” settings in Mach3