7.2.3 Reading the current ohmic values of the sensors
Compatibility : - WaveTherm – PT100
- WaveTherm – PT1000
When using WaveTherm – PT100, or PT100 modules, it is possible to read the current ohmic value of the
sensors.
This type of reading may be started with one of several precision levels (0 to 3). In general, precision
level 0 is sufficient. The other precision levels are used in difficult environments (refer to chapter 7.2.1).
Applicative Command Description
0x07
Request to read the current ohmic value of the sensors
0x87
Response to request to read the current ohmic value of the sensors
Contents of request REQ_SEND_FRAME
Data Field (max : 152 bytes)
Applicative Command
Precision level
1 byte
1 byte
0x07
Contents of the response RECEIVED_FRAME
Data Field (max : 152 bytes)
Acknowledgement
of the Applicative
Command
Operating
Mode
Application
Status
Resistance A
(32-bit Float
LSB First)
Resistance B
(32-bit Float
LSB First)
1 byte
1 byte
1 byte
4 bytes
4 bytes
0x87
The format of the temperature is described in chapters 5.1.1 and 5.2.