File : CS-SUP-MUTI-WTHERMAPP-E01.sxw
7.1.4 Setting the date and time of the module
Applicative
command
Description
0x13
Request to set the date and time of the module
0x93
Response to request to set the date and time of the module
Remark :
In the command byte coding, the Response frame type are taking the Request command byte
value with the MSB bit set to 1.
➢
Contents of request REQ_SEND_FRAME
Data Field (max : 152 bytes)
Applicative
command
Day
Month
Year
Day of the
week
Hour
Minute
1 byte
1 byte
1 byte
1 byte
1 byte
1 byte
1 byte
0x13
(1)
(2)
(1)
Year
= current year - 2000
(2)
day of the week : value from 0 to 6
Value
Day of Week
0
Sunday
1
Monday
2
Tuesday
3
Wednesday
4
Thursday
5
Friday
6
Saturday
➢
Contents of response RECEIVED_FRAME
Data Field (max : 152 bytes)
Acknowledgement of
the applicative
command
Update Status
-
1 byte
1 byte
-
0x93
0x00 : update OK
0xFF : update error
-
WaveTherm modules – application handbook
page 30 of 65