File : CS-SUP-MUTI-WTHERMAPP-E01.sxw
The data field of each command must be formatted according to the following table :
CMD
DATA
6 bytes
variable ( max : 152 bytes)
0x20
Radio address from equipment to reach
Data to transmit
0x30
Radio address from transmitter
equipment
Received Data
the first byte of the field 'data to transmit' (or 'Received Data') contains an applicative command (or its
acknowledgement). That allows to the receptor of the frame to identify the type of requests (or of responses).
Data to Transmit or Received Data
1 byte
151 bytes
REQ_SEND_FRAME
Applicative command
Data relating to the request
RECEIVED_FRAME
Acknowledgement of the
applicative command
Data relating to the response
The commands set is available in Appendix A.
ATTENTION, This document describes only the format of the fields 'Data to Transmit', 'Received Data'.
These fields are directly dependent on the access to the functionalities of the WaveTherm modules. The
other fields of the radio frame depend on the exchanges modes chosen, and are detailed in document
[DR1].
WaveTherm modules – application handbook
page 14 of 65