File : CS-SUP-MUTI-WTHERMAPP-E01.sxw
7.1.2 Reading of the firmware version
The firmware version of the module is obtained by interrogating the distant module with
GET_FIRMWARE_VERSION command.
Applicative
command
Description
0x28
Request of reading the firmware version (GET_FIRMWARE_VERSION)
0xA8
Response to the request of reading the firmware version
➢
Contents of request REQ_SEND_FRAME
Data Field (max : 152 bytes)
Applicative command
Data
1 byte
-
0x28
-
➢
Contents of response RECEIVED_FRAME
Data Field (max : 152 bytes)
Acknowledgement
of the applicative
command
Character 'V' in
ASCII format
Mode of transmission
Firmware version
1 byte
1 byte
2 bytes
2 bytes
0xA8
0x56
Default value = 0x00A3
Remark 1 :
The coding of the US firmware version takes the standard coding with the MSbit set to 1.
Example :
firmware
= 0x0104
firmware ( US version)
= 0x8104
Remark 2 :
Possible values for the mode of transmission
Value
868 MHz single channel 4800 baud
0x0012
868 MHz frequency hopping 9600 baud
0x00A3
Frequency Band from 902 Mhz to 928 Mhz – frequency hopping – 19200 baud
(US version)
0x00B9
WaveTherm modules – application handbook
page 28 of 65