6 MODIFICATION OF THE INTERNAL PARAMETERS
6.1 INTERNAL PARAMETERS LIST ACCESSIBLE BY RADIO COMMANDS
6.1.1 Parameters common to all WAVETHERM versions
The table below describes the internal parameters accessible by standard read and write commands.
N°
Description
Size
(in bytes)
Access
right
Default value
Hexa.
Decimal
0x01
Operating Mode
1
R/W
Depending of the
module used (see 6.1.5)
0x02
WakeUp system status word
1
R/W
0
0
0x03
Default WakeUp period (in second)
1
R/W
0x01
1
0x04
Start time for 1
st
time window
1
R/W
0x07
7
0x05
WakeUp period for 1
st
time window (in second)
1
R/W
0x01
1
0x06
Start time for 2
nd
time window
1
R/W
0x12
18
0x07
WakeUp period for 2
nd
time window (in second)
1
R/W
0x01
1
0x08
Enalbe time windows by day of the week
1
R/W
0xFF
255
0x09
Enable WakeUp periods by day of the week
1
R/W
0x00
0
0x0A
number of loop of the datalogging storage table
1
R
0x00
0
0x0B
Number of temperature values stored in the table (LSB first)
2
R
0x0000
0
0x19
Numbers of retries of transmission of alarm frames
1
R/W
0x03
3
0x1A
Delay between two retries of transmission of alarm frames
1
R/W
0x3C
60
0x20
Application Status
1
R/W
0x80
128
0x22
Alarm Configuration byte
1
R/W
0x00
0
0x80
Measurement Period (datalogging in time steps)
1
R/W
0x13
19
0x81
Start hour of the datalogging in time steps
1
R/W
0x08
8
0x82
Day of the week, or of the month (datalogging)
1
R/W
0x01
1
0x83
Time of measurement (datalogging once a week, or once a month)
1
R/W
0x08
8
0x85
Group number to use in polling mode
1
R/W
0x00
0
0x90
Date of detection of end of battery life
6
R/W
0
0
0xA1
Firmware version
1
R
-
-
0xA2
Battery life duration counter
2
R
Depending of the power
supply profile
0xB0
Number of repeaters used to transmit an alarm frame
1
R/W
0x00
0
0xB1
Address of the 1
st
repeater used to transmit an alarm frame
6
R/W
-
-
0xB2
Address of the 2
nd
repeater used to transmit an alarm frame
6
R/W
-
-
0xB3
Address of the 3
rd
repeater used to transmit an alarm frame
6
R/W
-
-
0xB4
Address of the recipient of the alarm frame
6
R/W
0x010A030
000BD
-
WaveTherm modules – application handbook