Part nuMber
descrIPtIon
XTL-230-18
Xenus XTL Servodrive 6/18 A
XTL-230-36
Xenus XTL Servodrive 12/36 A
XTL-230-40
Xenus XTL Servodrive 20/40 A
XTL-Ck
Xenus Solder-Cup Connector kit
CME2
CME 2
Configuration Software CD
SER-Ck
CME 2 RS-232 Cable kit
J5
Xenus XTL
™
DIGITAL SERVO DRIVE
for BRUSHLESS/BRUSH MOTORS
Copley Controls, 20 Dan Road, Canton, MA 02021, USA
Tel: 781-828-8090
Fax: 781-828-6547
Tech Support: E-mail: [email protected], Internet: http://www.copleycontrols.com
Page 26 of 30
RoHS
STAnD-ALOnE OPERATIOn
Computer:
PC or compatible with
166MHz with 64MB RAM minimum
266 MHz with 128MB RAM recommended
Serial port (RS-232)
Motion controller card
Using the minimum requirements will allow CME 2 to
run but the performance will be significantly reduced.
Xenus takes digital position commands in Pulse/Direction, or CW/CCW
format from an external controller or quadrature encoder signals from
a master-encoder for electronic gearing. Velocity or torque control can
be from ±10V, digital PWM signals.
CME 2
used for setup and configuration.
Digital reference signals,
Logic Inputs and Outputs
Motor Feedback
Resolver and
Temperature Sensor
ORDERInG GUIDE
This table shows parts to order for the
configuration on this page
See page 24~25 for other parts required
(motor, +24 Vdc power supply, etc.)
coM1
coM2
coMx
CME 2
Windows® 95, 98, 2000,
ME, and nT
ser
-
cK
XtL-cK
J8
J7
Motion
controller
Add -S to part numbers above for sin/cos feedback,
or add -R for resolver feedback models.