13
SECTION 10 RECOMMENDED SEPARATION DISTANCES BETWEEN PORTABLE AND
MOBILE RF COMMUNICATIONS EQUIPMENT AND ALLY UPS
(for all Medical Equipment and Medical Equipment Systems that are not Life Supporting)
The ALLY UPS is intended for use in an electromagnetic environment in which radiated RF disturbances are
controlled. The customer or the user of the ALLY UPS can help prevent electromagnetic interference by maintaining
a minimum distance between portable and mobile RF communications equipment (transmitters) and the ALLY UPS
as recommended below, according to the maximum output power of the communications equipment.
RATED MAXIMUM OUTPUT
POWER OF TRANSMITTER
IN WATTS
SEPARATION DISTANCE ACCORDING TO FREQUENCY OF TRANSMITTER
(Meters) [Notes 1 and 2]
150 kHz to 80 MHz
80 MHz to 800 MHz
800 MHz to 2,5 GHz
d
= 1.17
√P
d
= 1.17
√P
d
= 2.33
√P
0.01
0.117
0.117
0.233
0.1
0.37
0.37
0.737
1
1.17
1.17
2.33
10
3.7
3.7
7.37
100
11.7
11.7
23.3
SECTION 11 DISPOSAL
Dispose of in accordance with all applicable Federal, State, and Local Medical/Hazardous waste practices.
SECTION 12 ACCESSORIES
The following accessories are available from CooperSurgical.
DESCRIPTION PART NUMBER
Adapter Drape
AU-AD
Adapter Drape
AU-AD-DLNTR
CART AU-CART
SECTION 13 WARRANTY
CooperSurgical warrants that the ALLY UPS will be free from defects in materials and workmanship for one year
from the date of purchase. If CooperSurgical, Inc. determines that the ALLY UPS fails to perform within that one
year, as the sole remedy for that failure to perform, at CooperSurgical’s discretion, we will repair or replace the
ALLY UPS free of charge.
For transmitters rated at a maximum output power not listed above, the recommended separation distance
d
in meters (m) can
be determined using the equation applicable to the frequency of the transmitter, where
P
is the maximum output power rating of
the transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1:
At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2:
These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and
reflection from structures, objects and people.
ALLY Uterine Positioning System
®
(ENGLISH)
One of the AU Accessory Kits has been supplied with the ALLY UPS:
PART NUMBER
CONTENTS
AU-KITF
Power Cord IEC Type F; Rail Clamp UK/EURO
AU-KITG
Power Cord IEC Type G; Rail Clamp UK/EURO
AU-KITH
Power Cord IEC Type H; Rail Clamp UK/EURO
AU-KITM
Power Cord IEC Type M; Rail Clamp UK/EURO
AU-KITI
Power Cord IEC Type I; Rail Clamp DENYER