Convotherm 4 GS
6.10
6.20
10.10 10.20 12.20 20.10 20.20
1N~ 100V 50/60Hz
Rated power consumption
[kW]
0.5
0.5
0.5
0.5
0.5
1.0
1.0
Convection power
[kW]
0.1
0.1
0.1
0.1
0.1
0.2
0.2
Motor power
[kW]
0.35
0.35
0.35
0.35
0.35
0.7
0.7
Rated current
[A]
5.2
5.2
5.2
5.2
5.2
9.8
9.8
Fuse rating
[A]
16
16
16
16
16
16
16
Recommended conductor
cross-section for wires laid un‐
covered in air up to 5 m in
length.
[mm
2
]
3G2.5 3G2.5 3G2.5 3G2.5 3G2.5 3G2.5 3G2.5
Recommended residual-current
device
Type
A
A
A
A
A
A
A
Optional residual-current device Type
B/F
B/F
B/F
B/F
B/F
B/F
B/F
1N~ 230V 50/60Hz
Rated power consumption
[kW]
0.6
0.6
0.6
0.6
0.6
1.1
1.1
Convection power
[kW]
0.1
0.1
0.1
0.1
0.1
0.2
0.2
Motor power
[kW]
0.35
0.35
0.35
0.35
0.35
0.7
0.7
Rated current
[A]
2.3
2.3
2.3
2.3
2.3
4.3
4.3
Fuse rating
[A]
16
16
16
16
16
16
16
Recommended conductor
cross-section for wires laid un‐
covered in air up to 5 m in
length.
[mm
2
]
3G2.5 3G2.5 3G2.5 3G2.5 3G2.5 3G2.5 3G2.5
Recommended residual-current
device
Type
A
A
A
A
A
A
A
Optional residual-current device Type
B/F
B/F
B/F
B/F
B/F
B/F
B/F
1N~120V 60Hz
Rated power consumption
[kW]
0.5
0.5
0.5
0.5
0.5
1.0
1.0
Convection power
[kW]
0.1
0.1
0.1
0.1
0.1
0.2
0.2
Motor power
[kW]
0.4
0.4
0.4
0.4
0.4
0.7
0.7
Rated current
[A]
4.7
4.7
4.7
4.7
4.7
8.9
8.9
Fuse rating
[A]
16
16
16
16
16
16
16
Recommended conductor
cross-section for wires laid un‐
covered in air up to 5 m in
length.
[mm
2
]
3G2.5 3G2.5 3G2.5 3G2.5 3G2.5 3G2.5 3G2.5
Recommended residual-current
device
Type
A
A
A
A
A
A
A
Optional residual-current device Type
B/F
B/F
B/F
B/F
B/F
B/F
B/F
2~ 230 V 50/60Hz
Rated power consumption
[kW]
0.5
0.5
0.5
0.5
0.5
1.0
1.0
Convection power
[kW]
0.1
0.1
0.1
0.1
0.1
0.2
0.2
Motor power
[kW]
0.35
0.35
0.35
0.35
0.35
0.7
0.7
Rated current
[A]
2.3
2.3
2.3
2.3
2.3
4.3
4.3
Fuse rating
[A]
16
16
16
16
16
16
16
Recommended conductor
cross-section for wires laid un‐
covered in air up to 5 m in
length.
[mm
2
]
3G2.5 3G2.5 3G2.5 3G2.5 3G2.5 3G2.5 3G2.5
9 Technical data