Dimensions and connection points for C4 6.10 (disappearing door)
Front view
Connection points in appliance floor
Detailed view of drain connection
* Distance depends on how far the
appliance feet are extended (max. +25 mm)
View from above with wall clearances
Meaning of labelled elements
A Water connection Soft water G 3/4''
B Water connection Hard water G 3/4''
C Drain connection DN 50
D Electrical connection
E Equipotential bonding
F Rinse-aid connection (optional)
G Cleaning-agent connection (optional)
H Air vent
Æ
50 mm
I
Ventilation port
Æ
50 mm
J Gas connection
K Exhaust outlet
Æ
50 mm
M Safety overflow 80 x 25 mm
10 Connection diagrams
160
Содержание 4 10.10
Страница 1: ...Combi oven Read instructions before use Convotherm 4 Installation manual Original ENG...
Страница 2: ......
Страница 190: ......