Hardware RAID setup
●Rebuild failure (Read error)
A read error occurs from the source during rebuilding. Conduct restore in accordance
with the procedure described below.
Utiliry
Rebuild failure
This the restoration operation restores the error sector and not restores the data.
Because there is fear of the system may become unstable according to the data is
lost, recovers optionally in accordance.
<Restoration steps>
1.
Set the DIP switch for the mirror card for setting 1 with the power off.
※The DIP switch setteing refer to This Chapter “Switch setting” – “DIP switch”.
2.
After installing the mirror card, connect only a not replacement HDD to the mirror
card and turn on the power.
3.
Check this status.
Mirror card
DIP switch
setting 1
※Refer to This Chapter “Internal LED status.
※When the DIP switch is the setting 1, can not start Windows. Not Check by utility.
134
User’s Manual