Chapter
8
Hardware RAID setup
OS recovery setting
This section consists of notes on OS recovery with the mirror card connected.
Usually, you should perform recovery using recovery media after connecting two HDDs to
the mirror card.
If both HDDs connected to the mirror card recognize the card as normal, you can perform
recovery using recovery media and bypassing the above step.
However, if two HDDs, for example, used for other RAID system are to be
mirroring-configured, the mirror card may not be recognized as normal due to information
on mirroring configuration.
In this case, you need to manipulate the DIP switch for the mirror card. Conduct recovery
in accordance with the procedure described below.
1.
Set the DIP switch for the mirror card for setting 1 with the power off.
※The DIP switch setteing refer to This Chapter “Switch setting” – “DIP switch”.
2.
After installing the mirror card, turn on the power and check that the Access LED
on the mirror card flashes orange.
※Check visually the mirror card LED.
For more on the status of the mirror card LED, refer to This Chapter “Internal
LED status”.
3.
Turn off the power and set the DIP switch for the mirror card to normal status.
※How to set the DIP switch and installation/removal of the mirror card are the same
as step 1 of this procedure.
4.
After installing the mirror card, turn on the power and perform recovery.
※For more on how to perform recovery, refer to the “Windows Setup Procedure
Manual” accompanying the recovery media.
User’s Manual
131
Содержание VPC-2000
Страница 1: ...FA PC VPC Series VPC 2000 User s Manual CONTEC CO LTD...
Страница 2: ......
Страница 15: ...Chapter About the product Physical dimensions VPC 2000 mm Figure 2 1 VPC 2000 User s Manual 9...
Страница 18: ...Chapter About the product Motherboard Block chart Figure 2 4 Motherboard Block chart 12 User s Manual...
Страница 85: ...Chapter Software utirity 4 Language select Select a language and click Next 5 Setup Click Next User s Manual 79...
Страница 112: ...Chapter Software utirity 106 User s Manual...
Страница 122: ...Chapter Software RAID setup 3 Check Yes and select Next Input Name and Advanced arbitrarity 116 User s Manual...