Mounting Instructions
ProfiDAT
®
Data Transmission System
Programm 0514
MAL0514-0005b-EN
www.conductix.com
translated document
page 57 of 82
Fig. 53: Marking the profile
Measure the required distance to the cable penetrations in the support structure and mark the position on the ProfiDAT
®
profile.
Make markings on the insulating profile and the aluminum profile!
Fig. 54: Loosen the connector on the ProfiDAT
®
profile
Remove the marked profile (1). To do this, loosen the four lateral flange screws (2) and the threaded pins (3) of the two rail
connectors (4) on the left and right of the profile.
Move the rail connectors (4) so that the marked profile (1) can be removed. The insulating profiles (5) of the two adjacent pro-
files to the left and right may also need to be moved.
Fig. 55: Dismantling the ProfiDAT
®
profile
Remove the hanger clamps (6) with the marked profile (1). To do this, loosen the nut (7) and disc (8) and remove the hanger
clamp from the support structure (9).
Pull the ProfiDAT
®
profile (1) out of the hanger clamps (6).
Remove the insulating profile from the aluminum profile.
1
6
9
8
7
1
2
4
3
5