Mounting Instructions
ProfiDAT
®
Data Transmission System
Programm 0514
MAL0514-0005b-EN
www.conductix.com
translated document
page 56 of 82
Install trace heating in all ProfiDAT
®
profiles in the same way.
Lead the trace-heating cables out of the groove to the terminal box for the infeed.
CAUTION!
When connecting the ProfiDAT
®
profiles, make sure that the trace-heating cable is not damaged.
Before taking into operation, use an insulation tester (test voltage at least 500 V, maximum 2000
fold, minimum insulation resistance 500 Ohm/V) to check that the insulation of the heating cable
is undamaged.
6.4.15
Mounting a Temperature Sensor (optional)
The temperature sensor is connected directly to the ProfiDAT
®
profile.
Fig. 51: Temperature sensor at the infeed antenna
Fig. 52: Temperature sensor at the infeed antenna for funnel
Work steps:
The temperature sensor (1) is pre-installed on the infeed unit (2).
Run the temperature-sensor cable (3) to the profile-heating controller switching cabinet and connect it.
6.4.16
Retrofitting of a PE Rail Connector (Ground)
If the existing grounding of the profile is insufficient, a PE rail connector has to be retrofitted to the ProfiDAT
®
profile. The exact
position must be determined based on the system layout.
It is not possible to retrofit a PE rail connector in a system with C-rails!
Work steps:
Center the insulating profile on the aluminum profile so that both ends of the insulating profile are at the same distance from the
ends of the aluminum profile.
1
3
2