Mounting Instructions
ProfiDAT
®
Data Transmission System
Programm 0514
MAL0514-0005b-EN
www.conductix.com
translated document
page 28 of 82
4.3
Description of Assemblies
4.3.1
ProfiDAT
®
System
Fig. 3: Profile
Profile (slotted wave guide)
The profiles are used as a data channel. They are electrically conductive
and are simultaneously used as a protective conductor (PE).
The standard length of a profile is 5000 mm. The outer dimensions are
50 x 56 mm (width x height). The conductor cross-section is at least
585 mm².
Fig. 4: Hanger clamp
Hanger clamp
The rail clamps are attached to the supporting construction with nuts and
bolts, which are provided by the customer.
The hanger clamps are pushed onto the profiles. Two hanger clamps are
installed for each profile. The spacing between hanger clamps is
2500 mm.
Fig. 5: Hanger clamp for installation on a C-rail
Hanger clamp for installation on a 40 x 40-mm C-rail
Fig. 6: Anchor point
Anchor point
The anchor point is fixed to the hanger clamp and the PE rail connector
and is used to create a fixed point
.
Fig. 7: Rail connector
Fig. 8: PE rail connector
Rail connector
The rail connector connects two profiles together and is screwed onto
the profile.
There are two types of connectors:
Connector, simple
PE connector, with connection for a grounding cable
The ground cable is attached to the lug (PE rail connector).
There must be a PE connector every five profiles (every 25 m) and at
each expansion element.