Mounting Instructions
ProfiDAT
®
Data Transmission System
Programm 0514
MAL0514-0005b-EN
www.conductix.com
translated document
page 47 of 82
6.4.6
Installing the Entry Funnel
Systems with drive-in/out zones require the installation of an entry funnel so that the current collector can be driven in and out of the
profile.
Fig. 34: Installing the entry funnel
Work steps:
Push the entry funnel (1) onto the drive-in zone from underneath and fasten with two screws (2) with nuts (3) and washers (4).
CAUTION!
Note that there are left- and right-handed versions of the entry funnel!
Install the second entry funnel in the same way.
6.4.7
Adjusting the length of the ProfiDAT
®
Profile
The ProfiDAT
®
profiles at the ends of the section can be adjusted in length.
The insulating profile of the ProfiDAT
®
profile must always be 138 mm shorter than the aluminum
profile.
Work steps:
Determine the length of ProfiDAT
®
profile required.
Fig. 35: Trimming the ProfiDAT® profile
1
4
3
2