6
1.7
Delivery and Storage
To ensure consistent quality, each evaporative module is inspected before leaving the factory. If the module is
to be put into storage prior to installation, it must be stored under cover and protected from physical damage,
dust, frost and rain.
It is recommended that the evaporative module be kept in its transit packaging for as long as possible prior to
installation.
All evaporative modules are supplied flat-packed for assembly “in situ’. The evaporative module must
be assembled before water and electrical connections are made.
Please refer to
HE2
Evaporative Module Assembly Instructions supplied with the system.
Inspection
Upon receipt, remove the transit packaging and inspect the unit to ensure that no damage has occurred during
transit. Any visible damage must be reported to your
Condair distributor
immediately. If the unit is to be put
into storage, the packaging should be replaced.
1.8
Handling Evaporative Material
WARNING: the
HE2
evaporative material should not be cut or crushed as doing so may gener-
ate dust.
HE2
evaporative material is manufactured from glass fibre and is not classified as hazardous. It is recom-
mended that Personal Protection Equipment such as gloves, protective clothing and eye protection are used
during handling to protect the user from fibres or dust. If dust is generated during handling it is recommended
that respiratory protection is worn. Damage to the evaporative material will affect the performance of the
humidifier and may result in water carry over.
In the event of contact, the following procedures should be observed:
– Eye contact – wash well with water for a minimum of 15 minutes.
Skin contact – wash well with soap and water.
Contact your
Condair distributor
for COSHH data sheet if required.
1.9
Correct Method of Lifting
Lifting or handling must only be carried out by trained and qualified personnel. Ensure that the lifting operation
has been properly planned and risk assessed, and that all equipment has been checked by a skilled and
competent Health & Safety representative.
It is the customer's responsibility to ensure that operators are trained in handling heavy goods and to enforce
the relevant lifting regulations.
Any personnel handling or lifting the
HE2
system must follow the Lifting Operations and Lifting Equipment
Regulations 1998 and Approved Code of Practice L113. The regulation imposes duties on employers and self
employed persons and persons who have control, to any extent of lifting equipment.
The packaged
HE2
unit may be carried by fork lift from the underside, but caution should be exercised to
ensure that the load is balanced before lifting. Refer to weights and measures section for system weight.
1.10 Disposal
You must observe local laws and regulations when disposing of your
Condair
HE2
at the end of its
working life. Use personal protective equipment as recommended in the handling section above when
handling the evaporative material. In addition, respiratory protection should be worn to avoid inhala-
tion of dust or debris from the air flow which may have accumulated on the material.
The evaporative module is constructed from stainless steel which may be fully recycled.