3 - 1 4
l I n s t a l l a t i o n
C o n n e c t i n g t h e A f t e r c o o l e r a n d
O p t i o n a l P r e c o o l e r
( D 1 3 0 0 - 5 0 0 0 )
The aftercooler and/or optional precooler require a source of city, tower, or chiller water
and a discharge or return line. You can use water at temperatures of 45 to 85°F {7 to
29°C}.
1
Connect the water supply line to
the aftercooler or precooler inlet.
If a manual shut off valve is used,
it should be mounted on the inlet
line. Conair recommends that a
manual shut off valve be used on both
the supply and return lines.
2
Connect the water discharge or
return line to the aftercooler
or precooler outlet.
IMPORTANT:
Turn the water off when the dryer is not in use to prevent condensation.
aftercooler inlet
aftercooler outlet
2
TIP:
Make the water supply and
discharge / return connections
with flexible hoses at least 24 in.
(61 cm) long. This allows you to
easily remove the aftercooler as-
sembly for cleaning.
Recommended Water Flow Rates
Dryer Model
gal./min. {liters/min.}
600 15 {56.8}
800 15 {56.8}
1000 20 {75.7}
1300 25 {94.6}
1600 25 {94.6}
2000 25 {94.6}
2400 25 {94.6}
3200 30 {113.6}
4000 30 {113.6}
5000 30 {113.6}
IMPORTANT:
If an optional flow con-
trol is also being installed with the
aftercooler, the manual shut off
valve should be installed on the
inlet line for the flow control.
Содержание Carousel Plus D Series
Страница 6: ...iv l Table of Contents...
Страница 20: ...2 8 l Description...
Страница 40: ...3 8 l Installation...
Страница 54: ...4 14 l Operation Control Function Flow Charts From the Login Logout screen Home Login Screen 3...
Страница 74: ...4 34 l Operation Control Function Flow Charts From the Alarm screen Home Alarms Alarm Message Pop up...
Страница 90: ...4 50 l Operation...
Страница 91: ...4 O p e r a t i o n General Operation Stand Alone and ResinWorks Dryer Configuration Operation l 4 51...
Страница 112: ...5 16 l Maintenance...
Страница 208: ...C 46 l Appendix...