P r e p a r i n g f o r E l e c t r i c a l I n s t a l l a t i o n
1
Using the ModBus
cables provided,
connect the RTD box
to the heat source
being used (HTC,
ResinWorks, Gastrac
or standalone dryer)
for each hopper.
Repeat this for each
hopper and heat source
of the ModBus. Avoid
parallel runs with your
factory’s power cables,
and material conveying lines.
I n s t a l l i n g M o d B u s C a b l e S e t s
Cables are available in a wide variety of lengths and a cable assembly should be sup-
plied with each probe/junction box set in the system. Plan your installation appropri-
ately, determining which cable length has been selected for each hopper/junction box
with consideration to neat cable routing. Cables should be routed away from heated
surfaces, material conveying lines, or moving equipment and not run in parallel to
three-phase power lines. Support each cable as needed to prevent strain on the con-
nectors.
Carefully install each cable set from the remote heat source control to the hopper,
firmly screwing the connectors into place on each panel.
IMPORTANT:
Always
refer to the wiring dia-
grams that came with
your dryer to locate
specific electrical com-
ponents. Illustrations in
the User Guide are
intended to be repre-
sentative only.
CAUTION:
Always dis-
connect and lock out
the main power supply
before making electrical
connections. Electrical
connections should be
made only by qualified
personnel.
A p p e n d i x l
C - 1 5
NOTE:
RTD junction boxes connect
via Modbus to the heater control
and multiple heater controls are
daisy chain wired Modbus
connection back to the dryer
control.
✐
Содержание Carousel Plus D Series
Страница 6: ...iv l Table of Contents...
Страница 20: ...2 8 l Description...
Страница 40: ...3 8 l Installation...
Страница 54: ...4 14 l Operation Control Function Flow Charts From the Login Logout screen Home Login Screen 3...
Страница 74: ...4 34 l Operation Control Function Flow Charts From the Alarm screen Home Alarms Alarm Message Pop up...
Страница 90: ...4 50 l Operation...
Страница 91: ...4 O p e r a t i o n General Operation Stand Alone and ResinWorks Dryer Configuration Operation l 4 51...
Страница 112: ...5 16 l Maintenance...
Страница 208: ...C 46 l Appendix...