XSAT7080 X-Band Transceiver
Revision 0
Remote Control
MN/XSAT7080.IOM
4-12
Parameter
Type
Command
(Instruction
Code and
qualifier)
Arguments
for
Command
or
Response
to Query
Description of Arguments
Note that all arguments are ASCII
numeric codes between 48 and 57.
Response to
Command
(Slave to Master)
Query
(Instruction
code and
qualifier)
Response to Query
(Slave to Master)
Redundancy
Controller
Box
Auto/Manual
Mode
RAM= 1
byte,
value of 0,1
Command or Query.
RAM controls whether or not the Redundancy Controller
is in automatic or manual mode, where:
0 = Manual Mode,
1 = Auto Mode.
Example: RAM=1
RAM= (message ok)
RAM? (received ok,
But invalid
arguments found)
RAM?
RAM=
x
(same format as command
arguments)
Redundancy
Controller
Box Toggle
RTG= None Command
only.
RTG= sent to the online XSAT will cause the
Redundancy Box to toggle the Tx and Rx switches.
Example: RTG=
RTG= (message ok)
RTG? (received ok,
But invalid
arguments found)
N/A
N/A
Remote
Address
(Physical
Address)
SPA= 4
bytes,
numerical
Command or Query.
Physical Address - between 0001 and 9999.
Resolution 0001.
Example: SPA=0890
SPA= (message ok)
SPA? (received ok,
but invalid
arguments found)
SPA? SPA=
xxxx
(same format as command
arguments)
Remote
Baud rate
SBR=
4 bytes
Command or Query.
Baud Rate, as follows:
1200 = 1200 baud,
2400 = 2400 baud,
4800 = 4800 baud,
9600 = 9600 baud,
19K2 = 19200 baud.
38K4 = 38400 baud.
SBR= (message ok)
SBR? (received ok,
but invalid
arguments found)
SBR? SBR=xxxx
(same format as command
arguments)
Set RTC
Date
DAY= 6
bytes,
numerical
A command in the form mmddyy, where; dd = day of the
month, between 01 and 31, mm = month of the year,
between 01 and 12 and yy = year, between 97 and 96
(1997 to 2000, then 2000 to 2096)
Example: DAY=042457 would be April 24, 2057
DAY= (message ok)
DAY? (received ok,
but invalid
arguments found)
DAY* (message ok,
but not permitted in
current mode
DAY? DAY=xxxxxx
(same format as command
arguments