XSAT7080 X-Band Transceiver
Revision 0
Remote Control
MN/XSAT7080.IOM
4-8
Parameter
Type
Command
(Instruction
Code and
qualifier)
Arguments
for
Command
or
Response
to Query
Description of Arguments
Note that all arguments are ASCII
numeric codes between 48 and 57.
Response to
Command
(Slave to Master)
Query
(Instruction
code and
qualifier)
Response to Query
(Slave to Master)
Mute Mode
MUT=
1 byte,
value of 0,1
Command or Query.
Mute Mode, where:
0 = Unmuted after Frequency change,
1 = Muted after Frequency change.
Example: MUT=1
MUT=(message ok)
MUT?(received ok,
but invalid argument
found)
MUT? MUT=
x
(same format as command
argument)
Tx Mute
UMU=
1 byte,
value of 0,1
Command or Query.
Tx Mute, where:
0 = Transmitter Unmuted,
1 = Transmitter Muted
Example: UMU=1
UMU=(message ok)
UMU?(received ok,
but invalid argument
found)
UMU? UMU=
x
(same format as command
argument)
Rx Mute
DMU=
1 byte,
value of 0,1
Command or Query.
Rx Mute, where:
0 = Receiver Unmuted,
1 = Receiver Muted
Example: DMU=1
DMU=(message ok)
DMU?(received ok,
but invalid argument
found)
DMU? DMU=
x
(same format as command
argument)
Tx Slope
Mode
USM=
1 byte,
value of 0,1
Command or Query.
Tx Slope Mode, where:
0 =Manual Mode,
1 = Calibrated Mode.
Example: USM=1
USM=(message ok)
USM?(received ok,
But invalid argument
found)
USM? USM=
x
(same format as command
argument)
Tx Slope
Adjust
USA=
3 bytes
Command or Query.
Tx Slope Adjust, between 0.0 and 1.0.
Resolution = 0.1.
Example: USA=0.3
USA= (message ok)
USA? (received ok,
but invalid arg.
found)
USA? USA=
x.x
(same format as command
argument)
Rx Slope
Mode
DSM=
1 byte,
value of 0,1
Command or Query.
Rx Slope Mode, where:
0 =Manual Mode,
1 = Calibrated Mode.
Example: DSM=1
DSM=(message ok)
DSM?(received ok,
But invalid argument
found)
DSM? DSM=
x
(same format as command
argument)