Parameter
Type
Command
(Instruction
Code and
qualifier)
Arguments
for
Command
or
Response
to Query
Description of Arguments
Note that all arguments are ASCII
numeric codes between 48 and 57.
Response to
Command
(Slave to Master)
Query
(Instruction
code and
qualifier)
Response to Query
(Slave to Master)
XSAT Global
Configuration
CGC= 60
bytes,
with
numerical
entries
fixed value
entries, and
delimiters
Command or Query. Global configuration of Unit, in the
form: FFFF.FAA.AAMSB.BGG.GGZffff.faa.aamsb.b
gg.ggNRCXOOOLWWDeeeeeee, where:
F = Tx Frequency – same as UFQ= (6 bytes)
A = Tx Attenuation – same as UAT= (5 bytes)
M = Tx Mute – same ad UMU= (1byte)
S = Tx Slope Mode – same as USM= (1 byte)
B = Tx Slope Value – same as USA= (3 bytes)
G = Tx Gain Offset – same as UGO= (5 bytes)
Z = Tx Amplifier State – same as AMP= (1 byte)
f = Rx Frequency – same as UFQ= (6 bytes)
a = Rx Attenuation – same as UAT= (5 bytes)
m = Rx Mute – same ad UMU= (1byte)
s = Rx Slope Mode – same as USM= (1 byte)
b = Rx Slope Value – same as USA= (3 bytes)
g = Rx Gain Offset – same as UGO= (5 bytes)
N = Mute Mode – same as MUT= (1 byte)
R = Auto Fault Recovery – same as AFR= (1 byte)
C = Cold Start Mode – same as CLD= (1 byte)
X = Ext Ref Fault Logic – same as XRF= (1 byte)
O = Ref Oscillator Adjust – same as REF= (3 bytes)
L = LNA Current Source – same as LCS= (1 byte)
W = LNA Current Window – same as LCW= (3 bytes)
D = LNA Fualt Logic – same as LFL= (1 byte)
e = expansion (7 bytes), set to ‘0’
Example: CGC=7951.012.75000.3-0.0017251.0
12.75000.3-0.00110108719900000000
CGC= (message ok)
CGC? (received ok,
But invalid
arguments found)
CGC?
CGC= FFFF.FAA.AAMS
B.BGG.GGZffff.faa.aams
b.bgg.ggNRCXOOOLWWDeeeeee
e
(same format as command
arguments)