XSAT7080 X-Band Transciever
Revision 0
+10 dBm Model X-Band Transceiver
MN/XSAT7080.IOM
8–4
Common
Environmental
Conversion
Dual, No Spectral Inversion
Temperature:
Operating
Non-Operating
-40 to +55
°
C (-40 to 131
°
F)
-50 to +75
°
C (-58 to 167
°
F)
Sense
Positive, No Inversion
Attitude
15,000 Feet,
mean sea level
Frequency
Step Size
1 and 2.5 MHz automatic
Humidity
0 to 100 %, Relative
Frequency
Stability
±
1 x 10
-9
/day (maximum)
1 x 10
-7
/day
±
1 x 10
-8
/day (maximum)
-40 to 55
°
C (-40 to 131
°
F)
Rainfall
50
mm/hr
Attentuation
Steps
TX
TX (Optional)
RX
RX (Optional)
0 to 25 dB, in 0.25 dB steps
0 to 30 dB, in 0.25 dB steps
0 to 20 dB, in 0.25 dB steps
0 to 30 dB, in 0.25 dB steps
Solar Radiation
350 BTU/foot2/hour
Phase Noise
100 Hz
1 kHz
10 kHz
100 kHz
-66 dBc/Hz
-76 dBc/Hz
-86 dBc/Hz
-96 dBc/Hz
Prime Power
90 to 260 VAC Standard
47 to 63 Hz Standard
48 VDC Optional
Group Delay
Linear
Parabolic
Ripple
0.1 ns/MHz
0.02 ns/MHz
2
1 ns/p-p
M&C Methods
Both EIA-485 and EIA-232 Serial Interface
Handheld controller, optional
External
Reference
Connector
5 or 10 MHz EXT REF port available in
addition to internal frequency reference.
Redundant
Switch
Outdoor unit (ODU) with autoswitch on
failure
M&C Interface
M&C Interfaces between:
Transceivers and Switch
Switch and CMA compler
MTBF:
Transceiver
Switch
≥
50,000 hours
≥
90,000 hours
CE Mark
Meets CE Mark spec