XSAT7080 X-Band Transciever
Revision 0
+10 dBm Model X-Band Transceiver
MN/XSAT7080.IOM
8–3
8.2
Specifications
The following are the design, operating, and environmental specifications for the
XSAT-7080 unit.
Transmit
Receive
Frequency
7900 to 8400 MHz
RX Fequency
7250 to 7750 MHz
Intermodulation
Total OPBO = 6 dB
SCL = 9 dB OPBO,
∆
= 1 MHz
- 45 dBc
RX Gain
45
±
1 dB
TX Output Power, P1dB
+10 dBm
RX-IF Frequency
70
±
18 MHz
70
±
20 MHz (Optional)
140
±
36 MHz (Optional)
TX Gain
34
±
1.0 dB
Gain, without LNA
±
0.75 dB Full RF Band
±
0.25 dB constant temp
TX Gain Flatness
±
0.75 per 36 MHz
±
1.0 dB per 40 MHz
Gain Flatness
±
0.75 dB Full RF Band
±
0.75 per 36 MHz
±
1.0 dB per 40 MHz
TX Gain Stability
±
1.00 dB from –40 to +55
°
C
(-40 to 131
°
F)
Image Rejection
60 dB In-Band
2
nd
Harmonic
-55 dBc
RX Gain Stability, without
LNA, at 0 dBm Output Level
±
0.25 dB Constant C
±
1.00 dB –40 to +55
°
C
(-40 to 131
°
F)
Carrier Mute
-70 dBc
Output Power, P1dB
+13 dBm
Transmit Spurious:
AC Line Harmonics
Signal Related
Signal Related, In-Band
Signal Independent
-45 dBc
< 500 kHz, –60 dbc
-65 dBc
-55 dBm
RX Noise Figure
11 dB (Typical
AM to PM Conversion
3 degrees at 6 dB OPBO from
related power
Intermodulation
-50 dBc for two tones at
0 dBm each, 1 MHz apart
IF Frequency Range
70
±
20 MHz
IF Output VSWR
1.25:1
IF Input VSWR
1.25:1
RF Input VSWR
1.25:1
RF Output VSWR
1.25:1
IF Output Impedance
50
Ω
RF Output Impedance
50
Ω
RF Input Impedance
50
Ω
IF Input Impedance
50
Ω
RF Input/Output Connectors
Type N (Female)
TX Noise Figure
15 dB (Typical)
IF Output Connector
Type N (Female)
IF Input/Output Connectors
Type N (Female)