XSAT7080 X-Band Transceiver
Revision 0
Remote Control
MN/XSAT7080.IOM
4-16
Parameter
Type
Command
(Instruction
Code and
qualifier)
Arguments
for
Command
or
Response
to Query
Description of Arguments
Note that all arguments are ASCII
numeric codes between 48 and 57.
Response to
Command
(Slave to Master)
Query
(Instruction
code and
qualifier)
Response to Query
(Slave to Master)
Retrieve
Redundancy
Status
N/A
37 bytes,
alpha
numerical
Query only.
Used to Query the utility status of the XSAT
Example: RRS=’cr’
R 5V=5.0’cr’
R 12V=11.8’cr’
TX SW=OK’cr’
RX SW=OK’cr’’lf’
N/A RRS?
RRS=
x….x
(see description for
details of arguments)
Retrieve
Maintenance
Status
N/A
175 bytes,
alpha
numerical
Query only.
Used to Query the maintenance status of the XSAT
Example: RMS=’cr’
24VT=023.9’cr’
20VT=020.3’cr’
12VT=012.0’cr’
10VT=010.2’cr’
P5VT=005.0’cr’
N5VT=-05.0’cr’
USYN=008.2’cr’
UIFL=003.9’cr’
DSYN=006.3’cr’
DIFL=003.8’cr’
REFV=002.9’cr’
LNAC=081.9’cr’
FANC=541.0’cr’
UTMP= 37.0’cr’
POWR=25.0-’cr’
DTMP= 34.0’cr’’lf’
N/A RMS?
RMS=
x….x
(see description for
details of arguments)