XSAT7080 X-Band Transceiver
Revision 0
Remote Control
MN/XSAT7080.IOM
4-7
Parameter
Type
Command
(Instruction
Code and
qualifier)
Arguments
for
Command
or
Response
to Query
Description of Arguments
Note that all arguments are ASCII
numeric codes between 48 and 57.
Response to
Command
(Slave to Master)
Query
(Instruction
code and
qualifier)
Response to Query
(Slave to Master)
Tx
Frequency
UFQ=
6 bytes
numerical
Command or Query.
Tx Frequency in valid range.
Frequency divisible by 1Mhz and 2.5 MHz are allowed.
Example: UFQ= 7951.0
UFQ= (message ok)
UFQ? (received ok,
but invalid
arguments found)
UFQ? UFQ=
xxxx.x (
same format as
command arguments)
Rx
Frequency
DFQ=
6 bytes
numerical
Command or Query.
Rx Frequencyin valid range.
Frequency divisible by 1Mhz and 2.5 MHz are allowed.
Example: DFQ=7251.0
DFQ= (message ok)
DFQ? (received ok,
but invalid
arguments found)
DFQ? DFQ=
xxxx.x
(same format as
command arguments)
Tx
Attenuation
UAT=
5 bytes
numerical
Command or Query.
Tx Attenuation, in dB, between 00.00 and 25.00.
Resolution = 00.25 dB.
Example: UAT=12.75
UAT= (message ok)
UAT? (received ok,
but invalid
arguments found)
UAT?
UAT=
xx.xx
(same format as command
arguments)
Rx
Attenuation
DAT=
5 bytes
numerical
Command or Query.
Rx Attenuation, in dB, between 00.00 and 20.00.
Resolution = 00.25 dB.
Example: DAT=12.75
DAT= (message ok)
DAT? (received ok,
but invalid
arguments found)
DAT? DAT=
xx.xx
(same format as command
arguments)
Tx Gain
Offset
UGO=
5 bytes
numerical
Command or Query.
Tx Gain Offset for 1:1 redundancy configurations.
In dB, between -0.00 and -4.00. Resolution = 00.25 dB.
Example: UGO=-1.25
UGO= (message ok)
UGO? (received ok,
but invalid
arguments found)
UGO? UGO=
xx.xx
(same format as command
arguments)
Rx Gain
Offset
DGO=
5 bytes
numerical
Command or Query.
Rx Gain Offset for 1:1 redundancy configurations.
In dB, between -0.00 and -4.00. Resolution = 00.25 dB.
Example: DGO=-1.25
DGO= (message ok)
DGO? (received ok,
but invalid
arguments found)
DGO? DGO=
xx.xx
(same format as command
arguments)
Tx Amplifier
AMP=
1 byte,
value of
0,1
Command or Query.
Tx Amplifier, where:
0 = Amplifier OFF
1 = Amplifier ON
Example: AMP=1
AMP= (message ok)
AMP? (received ok,
but invalid argument
found)
AMP? AMP=
x
(same format as command
argument)