XSAT7080 X-Band Transceiver
Revision 0
Remote Control
MN/XSAT7080.IOM
4-19
Parameter
Type
Command
(Instruction
Code and
qualifier)
Arguments
for
Command
or
Response
to Query
Description of Arguments
Note that all arguments are ASCII
numeric codes between 48 and 57.
Response to
Command
(Slave to Master)
Query
(Instruction
code and
qualifier)
Response to Query
(Slave to Master)
Concise
Utility Status
N/A
10 bytes,
alpha
numerical
Query only.
Used to Query the Utility status of the XSAT
Example: CUS=brrru.ud.d’cr’’lf’
where:
b = baud rate, 1 = 1200, 2 = 2400,
3 = 4800, 4 = 9600, and 5 = 19200
rrr = reference adjust
u.u = Up converter slope adjust
d.d = Down converter slope adjust
N/A CUS?
CUS=
x….x
(see description for
details of arguments)
Concise
Maintenance
Status
N/A
80 bytes,
numerical
Query only.
Used to Query the Maintenance status of the XSAT
Example: CMS=aaa.abbb.bccc.cddd.deee.e
fff.fggg.ghhh.hiii.ijjj.jkkk.klll.lmmm.m
nnn.nooo.oppp.p’cr’’lf’
where:
aaa.a = 24V Power Supply
bbb.b = 20V Power Supply
ccc.c = 12V Power Supply
ddd.d = 10V Power Supply
eee.e = +5V Power Supply
fff.f = -5V Power Supply
ggg.g = Tx Synthesizer Tuning Voltage
hhh.h = Tx IFLO Tuning Voltage
iii.i = Rx Synthesizer Tuning Voltage
jjj.j = Rx IFLO Tuning Voltage
kkk.k = Reference Tuning Voltage
lll.l = LNA Current in milliamps
mmm.m = Fan Current in milliamps
nnn.n = Up Conv Heat Sink Temperature
ooo.o = RF Output Power in Db
ppp.p = Down Converter Temperature
N/A CMS?
CMS=
x….x
(see description for
details of arguments)