background image

PRODUCT INFORMATION 

BULLETIN 

 

 

 

105 Bonnie Drive 
Butler, PA 16002 
724-283-4681 
724-283-5939 (fax) 
www.bwieagle.com

 

 
 
 
 

 

 

 

AIR-EAGLE

®

 

XLT 

900 MHz RF Receiver 

MODEL 44P-8-ESTOP 

 

DESCRIPTION 

 

The A

IR

-E

AGLE 

XLT

 

is an RF system designed for long range wireless 

remote control of electrical apparatus in a variety of industrial applications.  
This receiver has been specifically designed for E-Stop applications. It 
links with an E-stop transmitter for failsafe operation. Dip switches allow 
the user to select link-loss shutdown times, relay operation and whether 
power must be recycled to reset the system. The relays are capable of 
switching up to 5 amps @120VAC or 30VDC and can be directly 
interfaced with the customer's equipment or P.L.C.  Seven user selectable 
frequencies allow multiple systems to be used in the same area. This 
receiver is capable of receiving remote signals transmitted from up to 
2500 feet away. 

 

INSTALLATION 

 

DISCONNECT AC Power from all equipment before installation. 

 

1. 

Mount the A

IR

-E

AGLE 

XLT R

ECEIVER

 in a convenient location.  

2. 

Select options & frequency (See OPTIONS & FREQUENCY SET-
UP) 

3. 

Install relay wiring to terminal strip. 

4. 

Install antenna onto connector located on the right side on the 
enclosure.   

5. 

Connect AC power to the proper terminals in your control circuit. 

 

TERMINAL STRIP WIRING 

N/O Relay #1 

N/O Relay #3 

13  120 VAC - (Neutral) 

C Relay #1 

C Relay #3 

14  120 VAC - (Hot) 

N/C Relay #1 

N/C Relay #3 

 

N/O Relay #2 

10  N/O Relay #4 

C Relay #2 

11  C Relay #4 

N/C Relay #2 

12  N/C Relay #4 

 

GENERAL OPERATION 

 

Prior to operation the user selects various options that control the link-loss 
shutdown, relay activation and system reset. (See OPTIONS & 
FREQUENCY SET-UP).  

 

When power is applied to the receiver, all relays will be in their de-
energized state. When power is applied to the E-stop transmitter, it 
immediately begins sending a beacon signal that causes the selected 
relays in the receiver to energize, indicating the communications link. 
Upon an E-stop command, the selected relays immediately de-energize. 
Upon specified link-loss time, the selected relays de-energize. The system 
will then need to be manually reset or will automatically come back online 
as designated by the system operation option selected. 
 

 

Dimensions (with mounting plate)  6.3” L  x  4.8” W  x 2.3” H

 

 
 

CONTROLS AND INDICATORS 

 

 

 

LED1 

Illuminated when power is applied to receiver 

LED2 

Illuminated when relay #1 is energized 

LED3 

Illuminated when relay #2 is energized 

LED4 

Illuminated when relay #3 is energized 

LED5 

Illuminated when relay #4 is energized 

RF1 

RF module that receives data from the remote 
transmitter 

REL1 thru REL4 

Four SPDT output control relays  

 

Отзывы: