LGaN
Revision 0
Serial Interface Operation
5–18
MN-LGAN
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII
numeric codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to
Query
(Target to
Controller)
Lamp Test
LAM=
1 byte
Command or Query.
Lamp test mode,
Where:
0 = Disable LED (turn off)
1 = Enable (Tri-color LED light)
2 = Test (cycles through colors once
Example:
<0001/LAM=1’cr’
>0001/LAM=1’cr’’lf’
Default Value: 0
LAM=
LAM?
LAM=x
LNB Current
Source
LCS=
1 byte
Command or Query.
This command enables, or disables the LNB current source. Note:
LCS must be enabled before the LNB current can be calibrated.
0 = Disable
1 = Enable
Example: <1/LCS=1’cr’
>0001/LCS=’cr’’lf’
Default Value: 0
LCS=
LCS?
LCS*
LCS?
LCS=x
(Same format
as command
arguments)
LNB Current
Window
LCW=
2 bytes
Command or Query.
This command allows the user to set the alarm window in
±
% of the
calibrated LNB Current. Valid inputs are 20 to 50 in increments of 1%.
In addition, setting the value to 99
1
disables the alarm function.
*Note: A return value of 99 indicates that the current window is
disabled. This may be because a value of 99 was set for LCW,
or it may be because the CWE has been disabled. Since the
method of setting 99 to this command is being obsoleted, it is
recommended the user utilize CWE instead of 99.
The following example will set the alarm window to
±
30%.
Example: <1/LCW=30’cr’
>0001/LCW=’cr’’lf’
Default Value: 30
LCW=
LCW?
LCW*
LCW?
LCW=xx
(Same format
as command
arguments)
Retrieve next 5
unread Stored
Alarms
N/A
145 bytes
Query only.
See RNE query.
LNA=
LNA?
See RNE
query
Содержание LGAN
Страница 22: ...L GaN Revision 0 Introduction 1 8 Figure 1 4 LGaN 50 W Dimensional Envelope 2 of 2...
Страница 24: ...L GaN Revision 0 Introduction 1 10 Figure 1 6 LGaN 100 W Ku Band Dimensional Envelope 2 of 2...
Страница 36: ...LGaN Revision 0 System Connectors Installation and Startup 2 12 MN LGAN BLANK PAGE...
Страница 117: ......
Страница 118: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...