LGaN
Revision 0
System Connectors, Installation, and Startup
2–2
MN-LGAN
2.2
Water Tight Sealing
All external cable assemblies for the outdoor equipment MUST be properly sealed to
prevent water intrusion. Failure to achieve water tight sealing will result in possible
performance degradation and even product failure.
IMPORTANT:
To maintain your product warranty, you must follow these guidelines and
recommendations during equipment installation:
•
Make sure all external connections to the equipment are hand-tightened and wrapped with a self-
amalgamating tape such as
3M Type 23
Scotch Self-Amalgamating Tape
(or equivalent). The
sealing must cover the external connector housing and extend beyond the end of the heatshrink
that covers the connector termination of the cable assembly.
•
Squeeze the self-amalgamating tape tightly and make sure both ends of the tape have formed
around the connector and cable to create a water tight seal.
•
ALL unused external connectors MUST be covered with caps and sealed. Make sure to inspect
the connector cap rubber seal for cracks before using.
2.2.1 Customer Cable Assemblies
Should you receive an accessory kit that contains only the mating cable connectors,
or if you (the end-user) choose to supply your own cables and connectors, CEFD
strongly recommends that you use an adhesive lined heatshrink such as TE
Connectivity #ATUM-24/6-0 (or equivalent) to cover the connector strain-relief area.
Your sealed, water tight cable ends should appear as per this example:
Содержание LGAN
Страница 22: ...L GaN Revision 0 Introduction 1 8 Figure 1 4 LGaN 50 W Dimensional Envelope 2 of 2...
Страница 24: ...L GaN Revision 0 Introduction 1 10 Figure 1 6 LGaN 100 W Ku Band Dimensional Envelope 2 of 2...
Страница 36: ...LGaN Revision 0 System Connectors Installation and Startup 2 12 MN LGAN BLANK PAGE...
Страница 117: ......
Страница 118: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...