LGaN
Revision 0
Serial Interface Operation
5–26
MN-LGAN
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII
numeric codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to
Query
(Target to
Controller)
Retrieve
Configuration
Status
(Cont)
LRS = 1’lf’ (see Note)
Note: XRF will always be N/A if the internal reference oscillator
option is not installed.
Retrieve
Equipment
Type
N/A
22 bytes
Query only.
The unit returns a string indicating the Model Number and the
version of the M&C firmware installed in the unit.
Example:
<1/RET?’cr’
>0001/RET= TRP500-4450-C-OD VER: 1.1.1’cr’’lf’
RET=
RET?
RET=x….x
(See
description for
details of
arguments)
RF Power FET
Current Status
N/A
Variable length,
depending on
the number of
FETs installed
in the RF
amplifier
Query only.
Used to display all the FET currents.
Example:
<0001/RFS?
>0001/RFS=
Q01=.000
Q02=.000
Q03=.000
Q04=.000
RFS=
RFS?
RFS=x….x
(See
description of
arguments)
Retrieve
Maintenance
Status
N/A
Varies
depending on
hardware
Query only.
Response dependent on configuration.
The unit returns the maintenance status as follows:
RMS?X
Where:
X= ‘cr’, 1’cr’
‘cr’ = Power Supply
1 = RF Module
Power Supply:
PFAN1 = PS Fan Speed in Percent
PS24V = PS 24V Voltage
PS24V = PS 24V Current
PS13V = PS 13.5V Voltage
P5V8T = 5.8V Voltage
P5V0T = 5.0V Voltage
P3V6T = 3.6V Voltage (250W)
P3V3T = 3.3V Voltage
RMS=
RMS*
RMS?
RMS=x….x
(See
description for
details of
arguments)
Содержание LGAN
Страница 22: ...L GaN Revision 0 Introduction 1 8 Figure 1 4 LGaN 50 W Dimensional Envelope 2 of 2...
Страница 24: ...L GaN Revision 0 Introduction 1 10 Figure 1 6 LGaN 100 W Ku Band Dimensional Envelope 2 of 2...
Страница 36: ...LGaN Revision 0 System Connectors Installation and Startup 2 12 MN LGAN BLANK PAGE...
Страница 117: ......
Страница 118: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...